Search Results (84164 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-7571 1 Schneider-electric 1 Webreports 2024-11-21 5.4 Medium
A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.
CVE-2020-7570 1 Schneider-electric 1 Webreports 2024-11-21 5.4 Medium
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Stored) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a Cross-Site Scripting stored attack against other WebReport users.
CVE-2020-7558 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7556 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7555 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7553 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7552 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7551 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7546 1 Schneider-electric 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more 2024-11-21 5.4 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
CVE-2020-7543 1 Schneider-electric 32 Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware, Modicon M340 Bmxp342000 and 29 more 2024-11-21 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
CVE-2020-7542 1 Schneider-electric 40 140cpu65150, 140cpu65150 Firmware, Modicon M340 Bmxp341000 and 37 more 2024-11-21 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
CVE-2020-7539 1 Schneider-electric 40 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 37 more 2024-11-21 7.5 High
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP.
CVE-2020-7538 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
CVE-2020-7537 1 Schneider-electric 38 Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware, Modicon M340 Bmxp342000 and 35 more 2024-11-21 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
CVE-2020-7536 1 Schneider-electric 20 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 17 more 2024-11-21 7.5 High
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.
CVE-2020-7524 1 Schneider-electric 2 Modicon M218, Modicon M218 Firmware 2024-11-21 7.5 High
Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal.
CVE-2020-7515 1 Schneider-electric 1 Easergy Builder 2024-11-21 7.8 High
A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password.
CVE-2020-7502 1 Schneider-electric 2 Modicon M218, Modicon M218 Firmware 2024-11-21 7.5 High
A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (Firmware version 4.3 and prior), which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller.
CVE-2020-7501 1 Schneider-electric 1 Vijeo Designer 2024-11-21 8.8 High
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.
CVE-2020-7498 1 Schneider-electric 2 Os Loader, Unity Loader 2024-11-21 9.8 Critical
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.