| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| disp+work 7400.12.21.30308 in SAP NetWeaver 7.40 allows remote attackers to cause a denial of service (resource consumption) via a crafted DIAG request, aka SAP Security Note 2405918. |
| Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account. |
| Improper cache invalidation in Joomla! CMS 1.7.3 through 3.7.2 leads to disclosure of form contents. |
| The function GfxImageColorMap::getGray in GfxState.cc in Poppler 0.54.0 allows remote attackers to cause a denial of service (stack-based buffer over-read and application crash) via a crafted PDF document, related to missing color-map validation in ImageOutputDev.cc. |
| The III_i_stereo function in layer3.c in mpglib, as used in libmpgdecoder.a in LAME 3.99.5 and other products, allows remote attackers to cause a denial of service (buffer over-read and application crash) via a crafted audio file that is mishandled in the code for the "block_type == 2" case, a similar issue to CVE-2017-11126. |
| The III_i_stereo function in layer3.c in mpglib, as used in libmpgdecoder.a in LAME 3.99.5 and other products, allows remote attackers to cause a denial of service (stack-based buffer overflow and application crash) or possibly have unspecified other impact via a crafted audio file. |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to a "Read Access Violation on Control Flow starting at FPX!GetPlugInInfo+0x0000000000012bf2." |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to a "User Mode Write AV starting at FPX!FPX_GetScanDevicePropertyGroup+0x0000000000007822." |
| In LibTIFF 4.0.8, there is a heap-based buffer overflow in the t2p_write_pdf function in tools/tiff2pdf.c. This heap overflow could lead to different damages. For example, a crafted TIFF document can lead to an out-of-bounds read in TIFFCleanup, an invalid free in TIFFClose or t2p_free, memory corruption in t2p_readwrite_pdf_image, or a double free in t2p_free. Given these possibilities, it probably could cause arbitrary code execution. |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to a "User Mode Write AV starting at FPX!DE_Decode+0x0000000000000cdb." |
| In LibTIFF 4.0.8, there is a memory leak in tif_jbig.c. A crafted TIFF document can lead to a memory leak resulting in a remote denial of service attack. |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to "Data from Faulting Address controls Code Flow starting at FPX!FPX_GetScanDevicePropertyGroup+0x000000000000c995." |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to "Data from Faulting Address controls Code Flow starting at FPX!FPX_GetScanDevicePropertyGroup+0x000000000000c998." |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to "Data from Faulting Address controls Code Flow starting at FPX+0x0000000000007236." |
| IrfanView version 4.44 (32bit) with FPX Plugin 4.46 allows attackers to execute arbitrary code or cause a denial of service via a crafted .fpx file, related to a "Read Access Violation on Block Data Move starting at FPX!FPX_GetScanDevicePropertyGroup+0x000000000000b84f." |
| In LibTIFF 4.0.8, there is a memory malloc failure in tif_jbig.c. A crafted TIFF document can lead to an abort resulting in a remote denial of service attack. |
| A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service condition. The service restarts automatically. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems. |
| A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network. |