| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group. |
| A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in RSM Design Website Template allows SQL Injection.This issue affects Website Template: before 1.2. |
| AVideo versions 14.3.1 prior to 20.1 contain an unauthenticated remote code execution vulnerability caused by predictable generation of an installation salt using PHP uniqid(). The installation timestamp is exposed via a public endpoint, and a derived hash identifier is accessible through unauthenticated API responses, allowing attackers to brute-force the remaining entropy. The recovered salt can then be used to encrypt a malicious payload supplied to a notification API endpoint that evaluates attacker-controlled input, resulting in arbitrary code execution as the web server user. |
| The Versa Concerto SD-WAN orchestration platform is vulnerable to an authentication bypass in the Traefik reverse proxy configuration, allowing at attacker to access administrative endpoints. The Spack upload endpoint can be leveraged for a Time-of-Check to Time-of-Use (TOCTOU) write in combination with a race condition to achieve remote code execution via path loading manipulation, allowing an unauthenticated actor to achieve remote code execution (RCE).This issue is known to affect Concerto from 12.1.2 through 12.2.0. Additional versions may be vulnerable. |
| An OS command injection vulnerability exists in the Chinese versions of Sangfor Endpoint Detection and Response (EDR) management platform versions 3.2.16, 3.2.17, and 3.2.19. The vulnerability allows unauthenticated attackers to construct and send malicious HTTP requests to the EDR Manager interface, leading to arbitrary command execution with elevated privileges. This flaw only affects the Chinese-language EDR builds. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| An Authentication Bypass Using an Alternate Path or Channel vulnerability in Juniper Networks Session Smart Router or conductor running with a redundant peer allows a network based attacker to bypass authentication and take full control of the device.
Only routers or conductors that are running in high-availability redundant configurations are affected by this vulnerability.
No other Juniper Networks products or platforms are affected by this issue.
This issue affects:
Session Smart Router:
* All versions before 5.6.15,
* from 6.0 before 6.1.9-lts,
* from 6.2 before 6.2.5-sts.
Session Smart Conductor:
* All versions before 5.6.15,
* from 6.0 before 6.1.9-lts,
* from 6.2 before 6.2.5-sts.
WAN Assurance Router:
* 6.0 versions before 6.1.9-lts,
* 6.2 versions before 6.2.5-sts. |
| Dolibarr ERP/CRM versions <= 3.1.1 and <= 3.2.0 contain a post-authenticated OS command injection vulnerability in its database backup feature. The export.php script fails to sanitize the sql_compat parameter, allowing authenticated users to inject arbitrary system commands, resulting in remote code execution on the server. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system.
A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network. |
| The Use of a Hard-coded Cryptographic Key vulnerability in Juniper Networks Juniper Cloud Native Router (JCNR) and containerized routing Protocol Deamon (cRPD) products allows an attacker to perform Person-in-the-Middle (PitM) attacks which results in complete compromise of the container.
Due to hardcoded SSH host keys being present on the container, a PitM attacker can intercept SSH traffic without being detected.
This issue affects Juniper Networks JCNR:
* All versions before 23.4.
This issue affects Juniper Networks cRPD:
* All versions before 23.4R1. |
| Kaleris NAVIS N4 ULC (Ultra Light Client) contains an unsafe Java deserialization vulnerability. An unauthenticated attacker can make specially crafted requests to execute arbitrary code on the server. |
| ReQuest Serious Play F3 Media Server 7.0.3 contains an unauthenticated remote code execution vulnerability that allows attackers to execute arbitrary commands as the web server user. Attackers can upload PHP executable files via the Quick File Uploader page, resulting in remote code execution on the server. |
| Multiple wireless router models from Sapido have an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. The affected models are out of support; replacing the device is recommended. |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| An information disclosure vulnerability in Phloc Webscopes 7.0.0 allows local attackers with access to the log files to view logged HTTP requests that contain user passwords or other sensitive information. |
| PTC Creo Elements/Direct License Server exposes a web interface which can be used by unauthenticated remote attackers to execute arbitrary OS commands on the server. |
| A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database. |
| A denial-of-service vulnerability exists in the Rockwell Automation Power Monitor 1000. The vulnerability results in a buffer-overflow, potentially causing denial-of-service. |