CVE Vendors Products Updated CVSS v3.1
CVE-2023-28004 1 Schneider-electric 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware 2024-08-02 9.8 Critical
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.
CVE-2023-27983 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-08-02 6.5 Medium
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27981 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-08-02 7.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27980 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-08-02 8.8 High
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
CVE-2023-27976 1 Schneider-electric 1 Ecostruxure Control Expert 2024-08-02 8.8 High
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-25619 1 Schneider-electric 14 Bmeh58s, Bmeh58s Firmware, Bmep58s and 11 more 2024-08-02 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
CVE-2023-25555 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 5.6 Medium
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25556 1 Schneider-electric 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more 2024-08-02 8.3 High
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 8.1 High
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 7.8 High
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25551 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 6.1 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25620 1 Schneider-electric 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more 2024-08-02 6.5 Medium
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 7.2 High
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25548 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 8.8 High
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25553 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 6.1 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25547 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 8.8 High
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25550 1 Schneider-electric 1 Struxureware Data Center Expert 2024-08-02 7.2 High
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-22611 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2024-08-02 7.5 High
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
CVE-2023-22610 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2024-08-02 9.1 Critical
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
CVE-2023-7032 1 Schneider-electric 1 Easergy Studio 2024-08-02 7.8 High
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object.