Filtered by vendor Tenda Subscriptions
Total 870 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-37712 1 Tenda 6 Ac1206, Ac1206 Firmware, F1202 and 3 more 2024-08-02 9.8 Critical
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
CVE-2023-37710 1 Tenda 4 Ac10, Ac10 Firmware, Ac1206 and 1 more 2024-08-02 9.8 Critical
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2023-37704 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-37706 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
CVE-2023-37701 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-37700 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-37703 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-37705 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
CVE-2023-37702 1 Tenda 2 Fh1203, Fh1203 Firmware 2024-08-02 9.8 Critical
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-37144 2 Tenda, Tendacn 2 Ac10, Ac10 Firmware 2024-08-02 9.8 Critical
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2023-34570 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
CVE-2023-34569 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-34567 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-34566 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-34571 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-34568 1 Tenda 2 Ac10, Ac10 Firmware 2024-08-02 6.7 Medium
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-33673 1 Tenda 2 Ac8, Ac8 Firmware 2024-08-02 9.8 Critical
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2023-33675 1 Tenda 2 Ac8, Ac8 Firmware 2024-08-02 9.8 Critical
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
CVE-2023-33672 1 Tenda 2 Ac8, Ac8 Firmware 2024-08-02 7.5 High
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
CVE-2023-33671 1 Tenda 2 Ac8, Ac8 Firmware 2024-08-02 9.8 Critical
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.