| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device. |
| Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000. |
| One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000. |
| Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs. |
| BWA DiREX-Pro 1.2181 devices allow remote attackers to execute arbitrary OS commands via shell metacharacters in the PKG parameter to uninstall.php3. |
| MISP 2.4.122 has Persistent XSS in the sighting popover tool. This is related to app/View/Elements/Events/View/sighting_field.ctp. |
| MISP 2.4.122 has reflected XSS via unsanitized URL parameters. This is related to app/View/Users/statistics_orgs.ctp. |
| CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. |
| An issue was discovered in Joomla! before 3.9.16. Inadequate handling of CSS selectors in the Protostar and Beez3 JavaScript allows XSS attacks. |
| An issue was discovered in Froxlor before 0.10.14. Remote attackers with access to the installation routine could have executed arbitrary code via the database configuration options that were passed unescaped to exec, because of _backupExistingDatabase in install/lib/class.FroxlorInstall.php. |
| In version 4.8.0 and earlier of The Sleuth Kit (TSK), there is a stack buffer overflow vulnerability in the YAFFS file timestamp parsing logic in yaffsfs_istat() in fs/yaffs.c. |
| A cross-site scripting (XSS) vulnerability in the messages module of vtecrm vtenext 19 CE allows attackers to inject arbitrary JavaScript code via the From field of an email. |
| npdf.dll in Nitro Pro before 13.13.2.242 is vulnerable to JBIG2Decode CNxJBIG2DecodeStream Heap Corruption at npdf!CAPPDAnnotHandlerUtils::create_popup_for_markup+0x12fbe via a crafted PDF document. |
| An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the date parameter in a system_time.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected. |
| An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the dns_query_name parameter in a dns_query.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected. |
| An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. There is a stack-based buffer overflow in the httpd binary. It allows an authenticated user to execute arbitrary code via a POST to ntp_sync.cgi with a sufficiently long parameter ntp_server. |
| An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the wps_sta_enrollee_pin parameter in a set_sta_enrollee_pin.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected. |
| Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH. |
| Command Injection in the CPE WAN Management Protocol (CWMP) registration in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows man-in-the-middle attackers to execute arbitrary commands with root level privileges. |
| Command Injection in EntoneWebEngine in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows authenticated remote attackers to execute arbitrary commands with root user privileges. |