Search Results (83164 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-13960 1 Libjpeg-turbo 1 Libjpeg-turbo 2024-11-21 N/A
In libjpeg-turbo 2.0.2, a large amount of memory can be used during processing of an invalid progressive JPEG image containing incorrect width and height values in the image header. NOTE: the vendor's expectation, for use cases in which this memory usage would be a denial of service, is that the application should interpret libjpeg warnings as fatal errors (aborting decompression) and/or set limits on resource consumption or image sizes
CVE-2019-13954 1 Mikrotik 1 Routeros 2024-11-21 N/A
Mikrotik RouterOS before 6.44.5 (long-term release tree) is vulnerable to memory exhaustion. By sending a crafted HTTP request, an authenticated remote attacker can crash the HTTP server and in some circumstances reboot the system. Malicious code cannot be injected.
CVE-2019-13952 1 Gdnsd 1 Gdnsd 2024-11-21 9.8 Critical
The set_ipv6() function in zscan_rfc1035.rl in gdnsd before 2.4.3 and 3.x before 3.2.1 has a stack-based buffer overflow via a long and malformed IPv6 address in zone data.
CVE-2019-13951 1 Gdnsd 1 Gdnsd 2024-11-21 N/A
The set_ipv4() function in zscan_rfc1035.rl in gdnsd 3.x before 3.2.1 has a stack-based buffer overflow via a long and malformed IPv4 address in zone data.
CVE-2019-13950 1 Syguestbook A5 Project 1 Syguestbook A5 2024-11-21 N/A
index.php?c=admin&a=index in SyGuestBook A5 Version 1.2 has stored XSS via a reply to a comment.
CVE-2019-13948 1 Syguestbook A5 Project 1 Syguestbook A5 2024-11-21 N/A
SyGuestBook A5 Version 1.2 allows stored XSS because the isValidData function in include/functions.php does not properly block XSS payloads, as demonstrated by a crafted use of the onerror attribute of an IMG element.
CVE-2019-13945 1 Siemens 32 S7-200 Smart, S7-200 Smart Firmware, Simatic S7-1200 and 29 more 2024-11-21 6.8 Medium
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
CVE-2019-13943 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2024-11-21 6.1 Medium
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.
CVE-2019-13936 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13935 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13934 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13931 1 Siemens 1 Xhq 2024-11-21 5.4 Medium
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13923 1 Siemens 2 Ie\/wsn-pa Link Wirelesshart Gateway, Ie\/wsn-pa Link Wirelesshart Gateway Firmware 2024-11-21 9.6 Critical
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
CVE-2019-13916 1 Cypress 3 Cyw20735b1, Cyw20819a1, Wiced Studio 2024-11-21 8.8 High
An issue was discovered in Cypress (formerly Broadcom) WICED Studio 6.2 CYW20735B1 and CYW20819A1. As a Bluetooth Low Energy (BLE) packet is received, it is copied into a Heap (ThreadX Block) buffer. The buffer allocated in dhmulp_getRxBuffer is four bytes too small to hold the maximum of 255 bytes plus headers. It is possible to corrupt a pointer in the linked list holding the free buffers of the g_mm_BLEDeviceToHostPool Block pool. This pointer can be fully controlled by overflowing with 3 bytes of packet data and the first byte of the packet CRC checksum. The checksum can be freely chosen by adapting the packet data accordingly. An attacker might be able to allocate the overwritten address as a receive buffer resulting in a write-what-where condition. This is fixed in BT SDK2.4 and BT SDK2.45.
CVE-2019-13915 1 B3log 1 Wide 2024-11-21 N/A
b3log Wide before 1.6.0 allows three types of attacks to access arbitrary files. First, the attacker can write code in the editor, and compile and run it approximately three times to read an arbitrary file. Second, the attacker can create a symlink, and then place the symlink into a ZIP archive. An unzip operation leads to read access, and write access (depending on file permissions), to the symlink target. Third, the attacker can import a Git repository that contains a symlink, similarly leading to read and write access.
CVE-2019-13767 5 Debian, Fedoraproject, Google and 2 more 5 Debian Linux, Fedora, Chrome and 2 more 2024-11-21 8.8 High
Use after free in media picker in Google Chrome prior to 79.0.3945.88 allowed a remote attacker who had compromised the renderer process to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13766 1 Google 1 Chrome 2024-11-21 6.5 Medium
Use-after-free in accessibility in Google Chrome prior to 77.0.3865.75 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13765 1 Google 1 Chrome 2024-11-21 6.5 Medium
Use-after-free in content delivery manager in Google Chrome prior to 78.0.3904.70 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13747 4 Debian, Fedoraproject, Google and 1 more 9 Debian Linux, Fedora, Android and 6 more 2024-11-21 8.8 High
Uninitialized data in rendering in Google Chrome on Android prior to 79.0.3945.79 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
CVE-2019-13741 4 Debian, Fedoraproject, Google and 1 more 8 Debian Linux, Fedora, Chrome and 5 more 2024-11-21 8.8 High
Insufficient validation of untrusted input in Blink in Google Chrome prior to 79.0.3945.79 allowed a local attacker to bypass same origin policy via crafted clipboard content.