CVE-2025-25727 2026-04-15 6.2 Medium
Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext.
CVE-2024-41336 2026-04-15 7.5 High
Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext.
CVE-2024-28736 1 Debezium Community Project 1 Debezium-ui 2026-04-15 7.1 High
An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function.
CVE-2024-28744 1 Furunosystems 2 Acera 9010-08 Firmware, Acera 9010-24 Firmware 2026-04-15 8.8 High
The password is empty in the initial configuration of ACERA 9010-08 firmware v02.04 and earlier, and ACERA 9010-24 firmware v02.04 and earlier. An unauthenticated attacker may log in to the product with no password, and obtain and/or alter information such as network configuration and user information. The products are affected only when running in non MS mode with the initial configuration.
CVE-2024-27143 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 9.8 Critical
Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL.
CVE-2025-6561 2026-04-15 9.8 Critical
Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-45775 1 Redhat 2 Enterprise Linux, Openshift 2026-04-15 5.2 Medium
A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data.
CVE-2024-2197 2026-04-15 4.3 Medium
The Chirp Access app contains a hard-coded password, BEACON_PASSWORD. An attacker within Bluetooth range could change configuration settings within the Bluetooth beacon, effectively disabling the application's ability to notify users when they are near a Beacon-enabled access point. This variable cannot be used to change the configuration settings of the door readers or locksets and does not affect the ability for authorized users of the mobile application to lock or unlock access points.
CVE-2025-22366 2026-04-15 N/A
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-2556 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2025-6560 2026-04-15 9.8 Critical
Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.  The affected models are out of support; replacing the device is recommended.
CVE-2025-2555 2026-04-15 2.9 Low
A vulnerability classified as problematic has been found in Audi Universal Traffic Recorder App 2.0. Affected is an unknown function of the component FTP Credentials. The manipulation leads to use of hard-coded password. Attacking locally is a requirement. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2024-11982 1 Billion Electric 4 M100, M120n, M150 and 1 more 2026-04-15 7.2 High
Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability. Remote attackers with administrator privileges can access the user settings page to retrieve plaintext passwords.
CVE-2025-37128 2 Arubanetworks, Hp 2 Edgeconnect Enterprise, Arubaos 2026-04-15 6.8 Medium
A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state.
CVE-2023-41092 2026-04-15 7.6 High
Unchecked return value in SDM firmware for Intel(R) Stratix 10 and Intel(R) Agilex 7 FPGAs before version 23.3 may allow an authenticated user to potentially enable denial of service via adjacent access.
CVE-2024-2038 1 Atarim 1 Visual Collaboration 2026-04-15 7.5 High
The Visual Website Collaboration, Feedback & Project Management – Atarim plugin for WordPress is vulnerable to unauthorized access in all versions up to, and including, 3.22.6. This is due to the use of hardcoded credentials to authenticate all the incoming API requests. This makes it possible for unauthenticated attackers to modify plugin settings, delete posts, modify post titles, and upload images.
CVE-2024-6834 2026-04-15 9 Critical
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2025-14096 1 Radiometer 5 Abl800 Basic Analyzer, Abl800 Flex Analyzer, Abl90 Flex Analyzer and 2 more 2026-04-15 8.4 High
A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.
CVE-2024-4232 2026-04-15 4.1 Medium
This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system.