| Hard-coded FTP credentials (r:r) are included in the Foscam C1 running firmware 1.9.1.12. Knowledge of these credentials would allow remote access to any cameras found on the internet that do not have port 50021 blocked by an intermediate device. |
| A vulnerability in Cisco Umbrella Insights Virtual Appliances 2.1.0 and earlier could allow an authenticated, local attacker to log in to an affected virtual appliance with root privileges. The vulnerability is due to the presence of default, static user credentials for an affected virtual appliance. An attacker could exploit this vulnerability by using the hypervisor console to connect locally to an affected system and then using the static credentials to log in to an affected virtual appliance. A successful exploit could allow the attacker to log in to the affected appliance with root privileges. Cisco Bug IDs: CSCvg31220. |
| A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device. |
| The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver https service with the tech account and an empty password, which allows remote attackers to obtain root privileges by establishing a session on port 49955 and then installing new software, such as BusyBox with "nc -l" support. |
| Huawei OceanStor 5600 V3 V300R003C00 has a hardcoded SSH key vulnerability; the hardcoded keys are used to encrypt communication data and authenticate different nodes of the devices. An attacker may obtain the hardcoded keys and log in to such a device through SSH. |
| A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132. |
| Hard-coded credentials in AmosConnect 8 allow remote attackers to gain full administrative privileges, including the ability to execute commands on the Microsoft Windows host platform with SYSTEM privileges by abusing AmosConnect Task Manager. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account. |
| The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue. |
| Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account. |
| Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC use non-random default credentials across all devices. A remote attacker can take complete control of a device using default admin credentials. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not). |
| The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904. |
| A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials. |
| iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file. |
| A Hard-Coded Passwords issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. The end user does not have the ability to change system passwords. |
| EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. |