Search Results (82847 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-19080 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ONVIF devicemgmt SetHostname method allows unauthenticated persistent XSS.
CVE-2018-19073 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow attackers to execute arbitrary OS commands via shell metacharacters in the modelName, by leveraging /mnt/mtd/app/config/ProductConfig.xml write access.
CVE-2018-19072 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. /mnt/mtd/app has 0777 permissions, allowing local users to replace an archive file (within that directory) to control what is extracted to RAM at boot time.
CVE-2018-19071 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. /mnt/mtd/boot.sh has 0777 permissions, allowing local users to control the commands executed at system start-up.
CVE-2018-19070 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow remote attackers to execute arbitrary OS commands via shell metacharacters in the usrName parameter of a CGIProxy.fcgi addAccount action.
CVE-2018-19069 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
CVE-2018-19067 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
CVE-2018-19066 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded Pxift* password in some cases.
CVE-2018-19065 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded BpP+2R9*Q password in some cases.
CVE-2018-19063 2 Foscam, Opticam 6 C2, C2 Application Firmware, C2 System Firmware and 3 more 2024-11-21 N/A
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
CVE-2018-19057 1 Sparksuite 1 Simplemde 2024-11-21 N/A
SimpleMDE 1.11.2 has XSS via an onerror attribute of a crafted IMG element, or via certain input with [ and ( characters, which is mishandled during construction of an A element.
CVE-2018-19056 1 Ipandao 1 Editor.md 2024-11-21 N/A
pandao Editor.md 1.5.0 has DOM XSS via input starting with a "<<" substring, which is mishandled during construction of an A element.
CVE-2018-19051 1 Metinfo 1 Metinfo 2024-11-21 N/A
MetInfo 6.1.3 has XSS via the admin/index.php?a=dogetpassword abt_type parameter.
CVE-2018-19050 1 Metinfo 1 Metinfo 2024-11-21 N/A
MetInfo 6.1.3 has XSS via the admin/index.php?a=dogetpassword langset parameter.
CVE-2018-19048 1 Mycolorway 1 Simditor 2024-11-21 N/A
Simditor through 2.3.21 allows DOM XSS via an onload attribute within a malformed SVG element.
CVE-2018-19041 1 Media File Manager Project 1 Media File Manager 2024-11-21 N/A
The Media File Manager plugin 1.4.2 for WordPress allows XSS via the dir parameter of an mrelocator_getdir action to the wp-admin/admin-ajax.php URI.
CVE-2018-19031 1 360 10 Safe Router P0, Safe Router P0 Firmware, Safe Router P1 and 7 more 2024-11-21 8.8 High
A command injection vulnerability exists when the authorized user passes crafted parameter to background process in the router. This affects 360 router series products (360 Safe Router P0,P1,P2,P3,P4), the affected version is V2.0.61.58897.
CVE-2018-19027 1 Omron 2 Cx-one, Cx-protocol 2024-11-21 N/A
Three type confusion vulnerabilities exist in CX-One Versions 4.50 and prior and CX-Protocol Versions 2.0 and prior when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19019 1 Omron 1 Cx-supervisor 2024-11-21 N/A
A type confusion vulnerability exists when processing project files in CX-Supervisor (Versions 3.42 and prior). An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19015 1 Omron 1 Cx-supervisor 2024-11-21 7.3 High
An attacker could inject commands to launch programs and create, write, and read files on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file. An attacker could exploit this to execute code under the privileges of the application.