A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack. |
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. |
Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. |
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). |
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. |
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. |
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. |
CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on
the network and potentially impacting connected devices. |
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become
unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network. |
CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss
of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the
controller and the engineering workstation while a valid user is establishing a communication session. This
vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks. |
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel
vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of
confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the
logical network while a valid user uploads or downloads a project file into the controller. |
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could
cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a
crafted Modbus function call to tamper with memory area involved in memory size computation. |
CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial
of service and loss of confidentiality & integrity when application user opens a malicious Zelio
Soft 2 project file. |
CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that could
compromise the Data Center Expert software when an upgrade bundle is manipulated to
include arbitrary bash scripts that are executed as root. |
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized
access, loss of confidentiality, integrity, and availability of the workstation when non-admin
authenticated user tries to perform privilege escalation by tampering with the binaries |
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized
access, loss of confidentiality, integrity and availability of the workstation when non-admin
authenticated user tries to perform privilege escalation by tampering with the binaries. |
CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability
exists that could cause a crash of the Accutech Manager when receiving a specially crafted
request over port 2536/TCP. |