| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| VMware Tools for Windows (11.x.y prior to 11.2.6), VMware Remote Console for Windows (12.x prior to 12.0.1) , VMware App Volumes (2.x prior to 2.18.10 and 4 prior to 2103) contain a local privilege escalation vulnerability. An attacker with normal access to a virtual machine may exploit this issue by placing a malicious file renamed as `openssl.cnf' in an unrestricted directory which would allow code to be executed with elevated privileges. |
| An issue was discovered in SaltStack Salt before 3003.3. A user who has control of the source, and source_hash URLs can gain full file system access as root on a salt minion. |
| The vCenter Server contains a local privilege escalation vulnerability due to the way it handles session tokens. A malicious actor with non-administrative user access on vCenter Server host may exploit this issue to escalate privileges to Administrator on the vSphere Client (HTML5) or vCenter Server vSphere Web Client (FLEX/Flash). |
| The vSphere Web Client (FLEX/Flash) contains an unauthorized arbitrary file read vulnerability. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to gain access to sensitive information. |
| In Bitnami Containers, all Laravel container versions prior to: 6.20.0-debian-10-r107 for Laravel 6, 7.30.1-debian-10-r108 for Laravel 7 and 8.5.11-debian-10-r0 for Laravel 8, the file /tmp/app/.env is generated at the time that the docker image bitnami/laravel was built, and the value of APP_KEY is fixed under certain conditions. This value is crucial for the security of the application and must be randomly generated per Laravel installation. If your application's encryption key is in the hands of a malicious party, that party could craft cookie values using the encryption key and exploit vulnerabilities inherent to PHP object serialization / unserialization, such as calling arbitrary class methods within your application. |
| vSphere Replication 8.3.x prior to 8.3.1.2, 8.2.x prior to 8.2.1.1, 8.1.x prior to 8.1.2.3 and 6.5.x prior to 6.5.1.5 contain a post-authentication command injection vulnerability which may allow an authenticated admin user to perform a remote code execution. |
| A privilege escalation vulnerability exists in the Remote Server functionality of Dream Report ODS Remote Connector 20.2.16900.0. A specially-crafted command injection can lead to elevated capabilities. An attacker can provide a malicious file to trigger this vulnerability. |
| An authentication bypass vulnerability exists in the get_aes_key_info_by_packetid() function of the home_security binary of Anker Eufy Homebase 2 2.1.6.9h. Generic network sniffing can lead to password recovery. An attacker can sniff network traffic to trigger this vulnerability. |
| An authentication bypass vulnerability exists in the process_msg() function of the home_security binary of Anker Eufy Homebase 2 2.1.6.9h. A specially-crafted man-in-the-middle attack can lead to increased privileges. |
| A specially-crafted HTTP request can lead to SQL injection. An attacker can make authenticated HTTP requests to trigger this vulnerability at ‘health_alt_filter’ parameter. This can be done as any authenticated user or through cross-site request forgery. |
| An exploitable SQL injection vulnerability exist in the ‘group_list’ page of the Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted HTTP request at '‘ord’ parameter. An attacker can make authenticated HTTP requests to trigger this vulnerability. This can be done as any authenticated user or through cross-site request forgery. |
| An exploitable SQL injection vulnerability exist in the ‘group_list’ page of the Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted HTTP request at 'description_filter’ parameter. An attacker can make authenticated HTTP requests to trigger this vulnerability. This can be done as any authenticated user or through cross-site request forgery. |
| An exploitable SQL injection vulnerability exist in the ‘group_list’ page of the Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted HTTP request at ‘company_filter’ parameter. An attacker can make authenticated HTTP requests to trigger this vulnerability. This can be done as any authenticated user or through cross-site request forgery. |
| A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability. |
| A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability. |
| A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability. |
| Specially-crafted command line arguments can lead to arbitrary file deletion in the del .cnt|.log file delete command. An attacker can provide malicious inputs to trigger this vulnerability |
| Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function. |
| Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device. |
| A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability |