| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in multiple models of Axis IP Cameras. There is Shell Command Injection. |
| There is a Cross-Site Scripting Vulnerability in Citrix XenMobile Server 10.7 before RP3. |
| SaferVPN 4.2.5 for Windows suffers from a SYSTEM privilege escalation vulnerability in its "SaferVPN.Service" service. The "SaferVPN.Service" service executes "openvpn.exe" using OpenVPN config files located within the current user's %LOCALAPPDATA%\SaferVPN\OvpnConfig directory. An authenticated attacker may modify these configuration files to specify a dynamic library plugin that should run for every new VPN connection attempt. This plugin will execute code in the context of the SYSTEM user. |
| CyberGhost 6.5.0.3180 for Windows suffers from a SYSTEM privilege escalation vulnerability through the "CG6Service" service. This service establishes a NetNamedPipe endpoint that allows arbitrary installed applications to connect and call publicly exposed methods. The "ConnectToVpnServer" method accepts a "connectionParams" argument that provides attacker control of the OpenVPN command line. An attacker can specify a dynamic library plugin that should run for every new VPN connection attempt. This plugin will execute code in the context of the SYSTEM user. |
| Golden Frog VyprVPN 2.12.1.8015 for Windows suffers from a SYSTEM privilege escalation vulnerability through the "VyprVPN" service. This service establishes a NetNamedPipe endpoint that allows applications to connect and call publicly exposed methods. The "SetProperty" method allows an attacker to configure the "AdditionalOpenVpnParameters" property and control the OpenVPN command line. Using the OpenVPN "plugin" parameter, an attacker may specify a dynamic library plugin that should run for every new VPN connection attempt. This plugin will execute code in the context of the SYSTEM user. This attack may be conducted using "VyprVPN Free" account credentials and the VyprVPN Desktop Client. |
| CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited. |
| Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller. |
| AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. |
| In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. |
| An out-of-bounds vulnerability in LeviStudioU, Versions 1.8.29 and 1.8.44 can be exploited when the application processes specially crafted project files. |
| Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow improper sanitization of data over a Websocket which may allow cross-site scripting and client-side code execution with target user privileges. |
| WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple heap-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files. |
| WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files. |
| IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow. |
| IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet. |
| Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution. |
| NetGain Enterprise Manager (EM) is affected by OS Command Injection vulnerabilities in versions before 10.0.57. These vulnerabilities could allow remote authenticated attackers to inject arbitrary code, resulting in remote code execution. |
| NetGain Enterprise Manager (EM) is affected by multiple Stored Cross-Site Scripting (XSS) vulnerabilities in versions before 10.1.12. |
| The "Latest Posts on Profile" plugin 1.1 for MyBB has XSS because there is an added section in a user profile that displays that user's most recent posts without sanitizing the tsubject (aka thread subject) field. |
| An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Hardcoded credentials exist for an unprivileged SSH account with a shell of /bin/false. |