| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A flaw was found in Openshift. A pod with a DNSPolicy of "ClusterFirst" may incorrectly resolve the hostname based on a service provided. This flaw allows an attacker to supply an incorrect name with the DNS search policy, affecting confidentiality and availability. |
| In JetBrains TeamCity between 2022.10 and 2022.10.1 connecting to AWS using the "Default Credential Provider Chain" allowed TeamCity project administrators to access AWS resources normally limited to TeamCity system administrators. |
| In applyKeyguardFlags of NotificationShadeWindowControllerImpl.java, there is a possible way to observe the user's password on a secondary display due to an insecure default value. This could lead to local information disclosure with no additional execution privileges needed. User interaction is needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-179725730 |
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings.
This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode. |
| In all Qualcomm products with Android releases from CAF using the Linux kernel, the use of an out-of-range pointer offset is potentially possible in rollback protection. |
| An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. |
| vsftpd on TP-Link C2 and C20i devices through firmware 0.9.1 4.2 v0032.0 Build 160706 Rel.37961n has a backdoor admin account with the 1234 password, a backdoor guest account with the guest password, and a backdoor test account with the test password. |
| A vulnerability in Cisco Elastic Services Controllers could allow an authenticated, remote attacker to log in to an affected system as the Linux admin user, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76651. Known Affected Releases: 21.0.0. |
| A vulnerability in AsyncOS for the Cisco Web Security Appliance (WSA) could allow an unauthenticated, local attacker to log in to the device with the privileges of a limited user or an unauthenticated, remote attacker to authenticate to certain areas of the web GUI, aka a Static Credentials Vulnerability. Affected Products: virtual and hardware versions of Cisco Web Security Appliance (WSA). More Information: CSCve06124. Known Affected Releases: 10.1.0-204. Known Fixed Releases: 10.5.1-270. |
| In F5 BIG-IP APM 12.0.0 through 12.1.2 and 13.0.0, an authenticated user with an established access session to the BIG-IP APM system may be able to cause a traffic disruption if the length of the requested URL is less than 16 characters. |
| Zyxel WRE6505 devices have a default TELNET password of 1234 for the root and admin accounts, which makes it easier for remote attackers to conduct DNS hijacking attacks by reconfiguring the built-in dnshijacker process. |
| wp-mail.php in WordPress before 4.7.1 might allow remote attackers to bypass intended posting restrictions via a spoofed mail server with the mail.example.com name. |
| Dropbox Lepton 1.2.1 allows DoS (SEGV and application crash) via a malformed lepton file because the code does not ensure setup of a correct number of threads. |
| A vulnerability in Cisco Ultra Services Framework Element Manager could allow an authenticated, remote attacker with access to the management network to log in as an admin or oper user of the affected device, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76699. Known Affected Releases: 21.0.0. |
| A vulnerability in Cisco Ultra Services Framework Staging Server could allow an authenticated, remote attacker with access to the management network to log in as an admin user of the affected device, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76681. Known Affected Releases: 21.0.0. |
| An issue was discovered in Pivotal Spring Web Flow through 2.4.5. Applications that do not change the value of the MvcViewFactoryCreator useSpringBinding property which is disabled by default (i.e., set to 'false') can be vulnerable to malicious EL expressions in view states that process form submissions but do not have a sub-element to declare explicit data binding property mappings. NOTE: this issue exists because of an incomplete fix for CVE-2017-4971. |
| A vulnerability in Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points running Cisco Mobility Express Software could allow an unauthenticated, remote attacker to take complete control of an affected device. The vulnerability is due to the existence of default credentials for an affected device that is running Cisco Mobility Express Software, regardless of whether the device is configured as a master, subordinate, or standalone access point. An attacker who has layer 3 connectivity to an affected device could use Secure Shell (SSH) to log in to the device with elevated privileges. A successful exploit could allow the attacker to take complete control of the device. This vulnerability affects Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points that are running an 8.2.x release of Cisco Mobility Express Software prior to Release 8.2.111.0, regardless of whether the device is configured as a master, subordinate, or standalone access point. Release 8.2 was the first release of Cisco Mobility Express Software for next generation Cisco Aironet Access Points. Cisco Bug IDs: CSCva50691. |
| EMC Elastic Cloud Storage (ECS) before 3.1 is affected by an undocumented account vulnerability that could potentially be leveraged by malicious users to compromise the affected system. |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. |