Total
204 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-26870 | 1 Dell | 1 Powerstoreos | 2024-09-17 | 7 High |
Dell PowerStore versions 2.1.0.x contain an Authentication bypass vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability under specific configuration. An attacker would gain unauthorized access upon successful exploit. | ||||
CVE-2021-41292 | 1 Ecoa | 5 Ecs Router Controller-ecs, Ecs Router Controller-ecs Firmware, Riskbuster and 2 more | 2024-09-17 | 9.8 Critical |
ECOA BAS controller suffers from an authentication bypass vulnerability. An unauthenticated attacker through cookie poisoning can remotely bypass authentication and disclose sensitive information and circumvent physical access controls in smart homes and buildings and manipulate HVAC. | ||||
CVE-2018-4852 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-09-17 | N/A |
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device. | ||||
CVE-2021-27453 | 1 Mesalabs | 1 Amegaview | 2024-09-17 | 7.3 High |
Mesa Labs AmegaView Versions 3.0 uses default cookies that could be set to bypass authentication to the web application, which may allow an attacker to gain access. | ||||
CVE-2022-1067 | 1 Lifepoint | 1 Patient Portal | 2024-09-17 | 6.5 Medium |
Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting. | ||||
CVE-2020-1618 | 1 Juniper | 16 Ex2300, Ex2300-c, Ex3400 and 13 more | 2024-09-17 | 6.3 Medium |
On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as root without any password. This issue might only occur in certain scenarios: • At the first reboot after performing device factory reset using the command “request system zeroize”; or • A temporary moment during the first reboot after the software upgrade when the device configured in Virtual Chassis mode. This issue affects Juniper Networks Junos OS on EX and QFX Series: 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S4; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R1-S7, 18.3R2. This issue does not affect Juniper Networks Junos OS 12.3. | ||||
CVE-2022-34372 | 1 Dell | 1 Powerprotect Cyber Recovery | 2024-09-17 | 9.8 Critical |
Dell PowerProtect Cyber Recovery versions before 19.11.0.2 contain an authentication bypass vulnerability. A remote unauthenticated attacker may potentially access and interact with the docker registry API leading to an authentication bypass. The attacker may potentially alter the docker images leading to a loss of integrity and confidentiality | ||||
CVE-2022-30623 | 1 Chcnav | 2 P5e Gnss, P5e Gnss Firmware | 2024-09-17 | 5.9 Medium |
The server checks the user's cookie in a non-standard way, and a value is entered in the cookie value name of the status and its value is set to true to bypass the identification with the system using a username and password. | ||||
CVE-2020-1637 | 1 Juniper | 1 Junos | 2024-09-16 | 7.2 High |
A vulnerability in Juniper Networks SRX Series device configured as a Junos OS Enforcer device may allow a user to access network resources that are not permitted by a UAC policy. This issue might occur when the IP address range configured in the Infranet Controller (IC) is configured as an IP address range instead of an IP address/netmask. See the Workaround section for more detail. The Junos OS Enforcer CLI settings are disabled by default. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D100; 15.1X49 versions prior to 15.1X49-D210; 17.3 versions prior to 17.3R2-S5, 17.3R3-S8; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R3-S2; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2-S1, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. | ||||
CVE-2022-22189 | 1 Juniper | 1 Contrail Service Orchestration | 2024-09-16 | 7.3 High |
An Incorrect Ownership Assignment vulnerability in Juniper Networks Contrail Service Orchestration (CSO) allows a locally authenticated user to have their permissions elevated without authentication thereby taking control of the local system they are currently authenticated to. This issue affects: Juniper Networks Contrail Service Orchestration 6.0.0 versions prior to 6.0.0 Patch v3 on On-premises installations. This issue does not affect Juniper Networks Contrail Service Orchestration On-premises versions prior to 6.0.0. | ||||
CVE-2020-5384 | 1 Rsa | 1 Multifactor Authentication Agent | 2024-09-16 | 8.4 High |
Authentication Bypass Vulnerability RSA MFA Agent 2.0 for Microsoft Windows contains an Authentication Bypass vulnerability. A local unauthenticated attacker could potentially exploit this vulnerability by using an alternate path to bypass authentication in order to gain full access to the system. | ||||
CVE-2021-35530 | 1 Hitachienergy | 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware | 2024-09-16 | 6 Medium |
A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. | ||||
CVE-2022-26865 | 1 Dell | 1 Supportassist Os Recovery | 2024-09-16 | 6.8 Medium |
Dell Support Assist OS Recovery versions before 5.5.2 contain an Authentication Bypass vulnerability. An unauthenticated attacker with physical access to the system may exploit this vulnerability by bypassing OS Recovery authentication in order to run arbitrary code on the system as Administrator. | ||||
CVE-2021-43935 | 1 Baxter | 10 Welch Allyn Connex Cardio, Welch Allyn Diagnostic Cardiology Suite, Welch Allyn Hscribe Holter Analysis System and 7 more | 2024-09-16 | 8.1 High |
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges. | ||||
CVE-2021-33017 | 1 Philips | 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more | 2024-09-16 | 8.1 High |
The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication. | ||||
CVE-2018-19000 | 1 Lcds | 1 Laquis Scada | 2024-09-16 | N/A |
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data. | ||||
CVE-2019-6551 | 1 Pangea-comm | 1 Fax Ata | 2024-09-16 | 7.5 High |
Pangea Communications Internet FAX ATA all Versions 3.1.8 and prior allow an attacker to bypass user authentication using a specially crafted URL to cause the device to reboot, which may be used to cause a continual denial-of-service condition. | ||||
CVE-2021-36308 | 1 Dell | 1 Networking Os10 | 2024-09-16 | 5.9 Medium |
Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an authentication bypass vulnerability. A remote unauthenticated attacker could exploit this vulnerability to gain access and perform actions on the affected system. | ||||
CVE-2020-10148 | 1 Solarwinds | 1 Orion Platform | 2024-09-16 | 9.8 Critical |
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected. | ||||
CVE-2021-43985 | 1 Myscada | 1 Mypro | 2024-09-16 | 9.1 Critical |
An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization. |