Filtered by vendor Tenda Subscriptions
Total 870 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-24170 1 Tenda 2 Ac18, Ac18 Firmware 2024-08-02 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat.
CVE-2023-24212 1 Tenda 2 Ax3, Ax3 Firmware 2024-08-02 9.8 Critical
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the timeType function at /goform/SetSysTimeCfg.
CVE-2023-24169 1 Tenda 2 Ac18, Ac18 Firmware 2024-08-02 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
CVE-2023-24164 1 Tenda 2 Ac18, Ac18 Firmware 2024-08-02 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
CVE-2023-24165 1 Tenda 2 Ac18, Ac18 Firmware 2024-08-02 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
CVE-2023-24167 1 Tenda 2 Ac18, Ac18 Firmware 2024-08-02 9.8 Critical
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
CVE-2023-23080 1 Tenda 10 Cp3, Cp3 Firmware, Cp7 and 7 more 2024-08-02 9.8 Critical
Certain Tenda products are vulnerable to command injection. This affects Tenda CP7 Tenda CP7<=V11.10.00.2211041403 and Tenda CP3 v.10 Tenda CP3 v.10<=V20220906024_2025 and Tenda IT7-PCS Tenda IT7-PCS<=V2209020914 and Tenda IT7-LCS Tenda IT7-LCS<=V2209020914 and Tenda IT7-PRS Tenda IT7-PRS<=V2209020908.
CVE-2023-4744 1 Tenda 2 Ac8, Ac8 Firmware 2024-08-02 9.8 Critical
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
CVE-2023-4498 1 Tenda 2 N300, N300 Firmware 2024-08-02 5.3 Medium
Tenda N300 Wireless N VDSL2 Modem Router allows unauthenticated access to pages that in turn should be accessible to authenticated users only
CVE-2023-2923 1 Tenda 2 Ac6, Ac6 Firmware 2024-08-02 6.3 Medium
A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-2649 1 Tenda 2 Ac23, Ac23 Firmware 2024-08-02 7.2 High
A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-0782 1 Tenda 2 Ac23, Ac23 Firmware 2024-08-02 7.2 High
A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640.
CVE-2024-41461 2 Tenda, Tendacn 3 Fh1201, Fh1201, Fh1201 Firmware 2024-08-02 9.8 Critical
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
CVE-2024-41465 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-08-02 7.5 High
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm.
CVE-2024-41459 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-08-02 8.8 High
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.
CVE-2024-41464 2 Tenda, Tendacn 3 Fh1201, Fh1201, Fh1201 Firmware 2024-08-02 9.8 Critical
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic
CVE-2024-41492 1 Tenda 1 Ax1806 Firmware 2024-08-02 7.5 High
A stack overflow in Tenda AX1806 v1.0.0.1 allows attackers to cause a Denial of Service (DoS) via a crafted input.
CVE-2024-41463 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-08-02 4.3 Medium
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat.
CVE-2024-41462 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-08-02 4.3 Medium
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient.
CVE-2024-41466 2 Tenda, Tendacn 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware 2024-08-02 7.5 High
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.