Filtered by vendor Tenda
Subscriptions
Total
870 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-41460 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-08-02 | 6.5 Medium |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic. | ||||
CVE-2024-40412 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2024-08-02 | 6.8 Medium |
Tenda AX12 v1.0 v22.03.01.46 contains a stack overflow in the deviceList parameter of the sub_42E410 function. | ||||
CVE-2024-40417 | 1 Tenda | 1 Ax1806 Firmware | 2024-08-02 | 6.5 Medium |
A vulnerability was found in Tenda AX1806 1.0.0.1. Affected by this issue is the function formSetRebootTimer of the file /goform/SetIpMacBind. The manipulation of the argument list leads to stack-based buffer overflow. | ||||
CVE-2024-40503 | 1 Tenda | 1 Ax12 Firmware | 2024-08-02 | 6.5 Medium |
An issue in Tenda AX12 v.16.03.49.18_cn+ allows a remote attacker to cause a denial of service via the Routing functionality and ICMP packet handling. | ||||
CVE-2024-39963 | 1 Tenda | 2 Ax12 Firmware, Ax9 Firmware | 2024-08-02 | 8 High |
AX3000 Dual-Band Gigabit Wi-Fi 6 Router AX9 V22.03.01.46 and AX3000 Dual-Band Gigabit Wi-Fi 6 Router AX12 V1.0 V22.03.01.46 were discovered to contain an authenticated remote command execution (RCE) vulnerability via the macFilterType parameter at /goform/setMacFilterCfg. | ||||
CVE-2024-34943 | 1 Tenda | 1 Fh1206 Firmware | 2024-08-02 | 9.8 Critical |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting. | ||||
CVE-2024-34942 | 1 Tenda | 1 Fh1206 Firmware | 2024-08-02 | 8.8 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand. | ||||
CVE-2024-33214 | 1 Tenda | 1 Fh1206 Firmware | 2024-08-02 | 7.5 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic. | ||||
CVE-2024-33180 | 2 Tenda, Tendacn | 3 Ac18, Ac18, Ac18 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. | ||||
CVE-2024-32285 | 1 Tenda | 1 W30e Firmware | 2024-08-02 | 8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. | ||||
CVE-2024-32311 | 1 Tenda | 1 Fh1203 Firmware | 2024-08-02 | 6.5 Medium |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | ||||
CVE-2024-32290 | 1 Tenda | 1 W30e Firmware | 2024-08-02 | 6.7 Medium |
Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. | ||||
CVE-2024-32313 | 1 Tenda | 1 Fh1205 Firmware | 2024-08-02 | 6.5 Medium |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function. | ||||
CVE-2024-32315 | 1 Tenda | 1 Fh1202 | 2024-08-02 | 4.7 Medium |
Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | ||||
CVE-2024-32310 | 1 Tenda | 1 F1203 Firmware | 2024-08-02 | 8 High |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. | ||||
CVE-2024-32320 | 1 Tenda | 1 Ac500 | 2024-08-02 | 5.9 Medium |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | ||||
CVE-2024-32303 | 1 Tenda | 1 Ac15 Firmware | 2024-08-02 | 8 High |
Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. | ||||
CVE-2024-32293 | 1 Tenda | 1 W30e Firmware | 2024-08-02 | 8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. | ||||
CVE-2024-32281 | 1 Tenda | 1 Ac7 Firmware | 2024-08-02 | 8.8 High |
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | ||||
CVE-2024-32314 | 1 Tenda | 1 Ac500 | 2024-08-02 | 3.8 Low |
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. |