| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on KONE Group Controller (KGC) devices before 4.6.5. FTP does not require authentication or authorization, aka KONE-03. |
| An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to cloud communication. This lack of device authentication allowed an attacker to impersonate any device by guessing or learning their MAC address. |
| An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based on an activation code derived from the device MAC address. By guessing valid MAC addresses or using MAC addresses printed on devices in shops and reverse engineering the protocol, an attacker would have been able to register previously unregistered devices to their account. When the rightful owner would have connected them after purchase to their WiFi network, the devices would not have registered with their account, would subsequently not have been controllable from the owner's mobile app, and would not have been visible in the owner's account. Instead, they would have been under control of the attacker. |
| A vulnerability in the Graphite web interface of the Policy and Charging Rules Function (PCRF) of Cisco Policy Suite (CPS) could allow an unauthenticated, remote attacker to access the Graphite web interface. The attacker would need to have access to the internal VLAN where CPS is deployed. The vulnerability is due to lack of authentication. An attacker could exploit this vulnerability by directly connecting to the Graphite web interface. An exploit could allow the attacker to access various statistics and Key Performance Indicators (KPIs) regarding the Cisco Policy Suite environment. |
| A vulnerability in the administrative web interface of Cisco Identity Services Engine (ISE) could allow an authenticated, remote attacker to gain additional privileges on an affected device. The vulnerability is due to improper controls on certain pages in the web interface. An attacker could exploit this vulnerability by authenticating to the device with an administrator account and sending a crafted HTTP request. A successful exploit could allow the attacker to create additional Admin accounts with different user roles. An attacker could then use these accounts to perform actions within their scope. The attacker would need valid Admin credentials for the device. This vulnerability cannot be exploited to add a Super Admin account. |
| Authentication bypass vulnerability in portal/account/register.php in versions of OpenEMR before 5.0.1.4 allows a remote attacker to access (1) portal/add_edit_event_user.php, (2) portal/find_appt_popup_user.php, (3) portal/get_allergies.php, (4) portal/get_amendments.php, (5) portal/get_lab_results.php, (6) portal/get_medications.php, (7) portal/get_patient_documents.php, (8) portal/get_problems.php, (9) portal/get_profile.php, (10) portal/portal_payment.php, (11) portal/messaging/messages.php, (12) portal/messaging/secure_chat.php, (13) portal/report/pat_ledger.php, (14) portal/report/portal_custom_report.php, or (15) portal/report/portal_patient_report.php without authenticating as a patient. |
| Incorrect access control in the database manager component in Odoo Community 10.0 and 11.0 and Odoo Enterprise 10.0 and 11.0 allows a remote attacker to restore a database dump without knowing the super-admin password. An arbitrary password succeeds. |
| Incorrect access control in the Password Encryption module in Odoo Community 9.0 and Odoo Enterprise 9.0 allows authenticated users to change the password of other users without knowing their current password via a crafted RPC call. |
| Incorrect access control in the portal messaging system in Odoo Community 9.0 and 10.0 and Odoo Enterprise 9.0 and 10.0 allows remote attackers to post messages on behalf of customers, and to guess document attribute values, via crafted parameters. |
| Incorrect access control in asset bundles in Odoo Community 9.0 through 11.0 and earlier and Odoo Enterprise 9.0 through 11.0 and earlier allows remote authenticated users to inject arbitrary web script via a crafted attachment. |
| Incorrect access control in the RPC framework in Odoo Community 8.0 through 11.0 and Odoo Enterprise 9.0 through 11.0 allows authenticated users to call private functions via RPC. |
| Incorrect access control in the password reset component in Odoo Community 11.0 and earlier and Odoo Enterprise 11.0 and earlier allows authenticated users to reset the password of other users by being the first party to use the secure token. |
| Intuit Lacerte 2017 has Incorrect Access Control. |
| Entes EMG12 versions 2.57 and prior The application uses a web interface where it is possible for an attacker to bypass authentication with a specially crafted URL. This could allow for remote code execution. |
| ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability. |
| Emerson AMS Device Manager v12.0 to v13.5. A specially crafted script may be run that allows arbitrary remote code execution. |
| Becton, Dickinson and Company (BD) Alaris Plus medical syringe pumps (models Alaris GS, Alaris GH, Alaris CC, and Alaris TIVA) versions 2.3.6 and prior are affected by an improper authentication vulnerability where the software does not perform authentication for functionality that requires a provable user identity, where it may allow a remote attacker to gain unauthorized access to various Alaris Syringe pumps and impact the intended operation of the pump when it is connected to a terminal server via the serial port. |
| NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device allows access to configuration files and profiles without authenticating the user. |
| Incorrect access control in the Dashboard API on Drobo 5N2 NAS version 4.0.5-13.28.96115 allows attackers to bypass authentication due to insecure token generation. |
| An insecure transport protocol used by Drobo Dashboard API on Drobo 5N2 NAS version 4.0.5-13.28.96115 allows attackers to intercept network traffic. |