| Change #4777 (introduced in October 2017) introduced an unforeseen issue in releases which were issued after that date, affecting which clients are permitted to make recursive queries to a BIND nameserver. The intended (and documented) behavior is that if an operator has not specified a value for the "allow-recursion" setting, it SHOULD default to one of the following: none, if "recursion no;" is set in named.conf; a value inherited from the "allow-query-cache" or "allow-query" settings IF "recursion yes;" (the default for that setting) AND match lists are explicitly set for "allow-query-cache" or "allow-query" (see the BIND9 Administrative Reference Manual section 6.2 for more details); or the intended default of "allow-recursion {localhost; localnets;};" if "recursion yes;" is in effect and no values are explicitly set for "allow-query-cache" or "allow-query". However, because of the regression introduced by change #4777, it is possible when "recursion yes;" is in effect and no match list values are provided for "allow-query-cache" or "allow-query" for the setting of "allow-recursion" to inherit a setting of all hosts from the "allow-query" setting default, improperly permitting recursion to all clients. Affects BIND 9.9.12, 9.10.7, 9.11.3, 9.12.0->9.12.1-P2, the development release 9.13.0, and also releases 9.9.12-S1, 9.10.7-S1, 9.11.3-S1, and 9.11.3-S2 from BIND 9 Supported Preview Edition. |
| An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. |
| A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions. |
| In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code. |
| The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows a remote attacker to exploit the misconfigured Cross-Origin Resource Sharing (CORS) mechanism. An unauthenticated, remote attacker could exploit this vulnerability to perform sensitive actions such as adding a new administrator account or changing the appliance’s settings. A malicious internal user could also gain administrator privileges of this appliance and use it to visit a malicious link that exploits this vulnerability. This could cause the application to perform sensitive actions such as adding a new administrator account or changing the appliance’s settings. An unauthenticated, remote attacker could add an administrator-level account or change the appliance's settings. |
| Imperva SecureSphere gateway (GW) running v13, for both pre-First Time Login or post-First Time Login (FTL), if the attacker knows the basic authentication passwords, the GW may be vulnerable to RCE through specially crafted requests, from the web access management interface. |
| Wizkunde SAMLBase may incorrectly utilize the results of XML DOM traversal and canonicalization APIs in such a way that an attacker may be able to manipulate the SAML data without invalidating the cryptographic signature, allowing the attack to potentially bypass authentication to SAML service providers. |
| Some Navarino Infinity functions, up to version 2.2, placed in the URL can bypass any authentication mechanism leading to an information leak. |
| ZUUSE BEIMS ContractorWeb .NET 5.18.0.0 allows access to various /UserManagement/ privileged modules without authenticating the user; an attacker can misuse these functionalities to perform unauthorized actions, as demonstrated by Edit User Details. |
| Command injection vulnerability in Citrix NetScaler ADC and NetScaler Gateway 11.0 before build 70.16, 11.1 before build 55.13, and 12.0 before build 53.13; and the NetScaler Load Balancing instance distributed with NetScaler SD-WAN/CloudBridge 4000, 4100, 5000 and 5100 WAN Optimization Edition 9.3.0 allows remote attackers to execute a system command or read arbitrary files via an SSH login prompt. |
| Ubiquiti UniFi 52 devices, when Hotspot mode is used, allow remote attackers to bypass intended restrictions on "free time" Wi-Fi usage by sending a /guest/s/default/ request to obtain a cookie, and then using this cookie in a /guest/s/default/login request with the byfree parameter. |
| If a malicious attacker has used another vulnerability to gain full control over a content process, they may be able to replace the alternate data resources stored in the JavaScript Start-up Bytecode Cache (JSBC) for other JavaScript code. If the parent process then runs this replaced code, the executed script would be run with the parent process' privileges, escaping the sandbox on content processes. This vulnerability affects Firefox < 60. |
| A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users. |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device. |
| A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue. |
| A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. |
| A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it. |
| A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations. |