Search Results (2062 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-2567 2026-04-15 9.8 Critical
An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation.
CVE-2025-62691 2 Intercom, Microsoft 2 Malion, Windows 2026-04-15 N/A
Security Point (Windows) of MaLion and MaLionCloud contains a stack-based buffer overflow vulnerability in processing HTTP headers. Receiving a specially crafted request from a remote unauthenticated attacker could lead to arbitrary code execution with SYSTEM privilege.
CVE-2025-14310 1 Rethinkdb 1 Rethinkdb 2026-04-15 N/A
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in rethinkdb.This issue affects rethinkdb: before 2.4.4.
CVE-2024-5023 1 Netflix 1 Consoleme 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0.
CVE-2025-34068 2026-04-15 N/A
An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC.
CVE-2025-46274 2026-04-15 9.8 Critical
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.
CVE-2025-40804 1 Siemens 1 Simatic 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization.
CVE-2024-10865 2026-04-15 N/A
Improper Input validation leads to XSS or Cross-site Scripting vulnerability in OpenText Advanced Authentication. This issue affects Advanced Authentication versions before 6.5.
CVE-2025-13510 1 Iskra 2 Ihub, Ihub Lite 2026-04-15 N/A
The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings.
CVE-2024-2882 2026-04-15 N/A
SDG Technologies PnPSCADA allows a remote attacker to attach various entities without requiring system authentication. This breach could potentially lead to unauthorized control, data manipulation, and access to sensitive information within the SCADA system.
CVE-2025-34320 1 Basis International 1 Bbj 2026-04-15 N/A
BASIS BBj versions prior to 25.00 contain a Jetty-served web endpoint that fails to properly validate or canonicalize input path segments. This allows unauthenticated directory traversal sequences to cause the server to read arbitrary system files accessible to the account running the service. Retrieved configuration artifacts may contain account credentials used for BBj Enterprise Manager; possession of these credentials enables administrative access and use of legitimate management functionality that can result in execution of system commands under the service account. Depending on the operating system and the privileges of the BBj service account, this issue may also allow access to other sensitive files on the host, including operating system or application data, potentially exposing additional confidential information.
CVE-2025-12592 1 Vivotek 1 Camera 2026-04-15 N/A
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.
CVE-2024-8986 2026-04-15 5.5 Medium
The grafana plugin SDK bundles build metadata into the binaries it compiles; this metadata includes the repository URI for the plugin being built, as retrieved by running `git remote get-url origin`. If credentials are included in the repository URI (for instance, to allow for fetching of private dependencies), the final binary will contain the full URI, including said credentials.
CVE-2025-10264 1 Digiever 7 Ds-1200, Ds-16x00, Ds-2100 and 4 more 2026-04-15 10 Critical
Certain models of NVR developed by Digiever has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remoter attackers to access the system configuration file and obtain plaintext credentials of the NVR and its connected cameras.
CVE-2025-10364 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10365 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10571 1 Abb 1 Ability Edgenius 2026-04-15 9.6 Critical
Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1.
CVE-2024-12297 2026-04-15 N/A
Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.
CVE-2025-64127 1 Zenitel 1 Tciv-3+ 2026-04-15 10 Critical
An OS command injection vulnerability exists due to insufficient sanitization of user-supplied input. The application accepts parameters that are later incorporated into OS commands without adequate validation. This could allow an unauthenticated attacker to execute arbitrary commands remotely.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.