CVE-2021-20600 | 1 Mitsubishielectric | 2 R12ccpu-v, R12ccpu-v Firmware | 2024-11-21 | 5.9 Medium |
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery. | ||||
CVE-2021-20599 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 9.1 Critical |
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password. | ||||
CVE-2021-20598 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 5.3 Medium |
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to lockout a legitimate user by continuously trying login with incorrect password. | ||||
CVE-2021-20597 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 9.1 Critical |
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to the target unauthorizedly by sniffing network traffic and obtaining credentials when registering user information in the target or changing a password. | ||||
CVE-2021-20596 | 1 Mitsubishielectric | 3 Fx3u-enet-l Firmware, Fx3u-enet-p502 Firmware, Fx3u-enet Firmware | 2024-11-21 | 7.5 High |
NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. | ||||
CVE-2021-20594 | 1 Mitsubishielectric | 16 R08psfcpu, R08psfcpu Firmware, R08sfcpu and 13 more | 2024-11-21 | 7.5 High |
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names. | ||||
CVE-2021-20592 | 1 Mitsubishielectric | 7 Got2000 Gt23, Got2000 Gt23 Firmware, Got2000 Gt25 and 4 more | 2024-11-21 | 7.5 High |
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions 1.170C through 1.256S allows a remote unauthenticated attacker to cause DoS condition on the MODBUS/TCP slave communication function of the products by rapidly and repeatedly connecting and disconnecting to and from the MODBUS/TCP communication port on a target. Restart or reset is required to recover. | ||||
CVE-2021-20591 | 1 Mitsubishielectric | 40 R00cpu, R00cpu Firmware, R01cpu and 37 more | 2024-11-21 | 7.5 High |
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition. | ||||
CVE-2021-20590 | 1 Mitsubishielectric | 12 Got2000 Gt25, Got2000 Gt25 Firmware, Got2000 Gt27 and 9 more | 2024-11-21 | 7.5 High |
Improper authentication vulnerability in GOT2000 series GT27 model VNC server versions 01.39.010 and prior, GOT2000 series GT25 model VNC server versions 01.39.010 and prior, GOT2000 series GT21 model GT2107-WTBD VNC server versions 01.40.000 and prior, GOT2000 series GT21 model GT2107-WTSD VNC server versions 01.40.000 and prior, GOT SIMPLE series GS21 model GS2110-WTBD-N VNC server versions 01.40.000 and prior and GOT SIMPLE series GS21 model GS2107-WTBD-N VNC server versions 01.40.000 and prior allows a remote unauthenticated attacker to gain unauthorized access via specially crafted packets when the "VNC server" function is used. | ||||
CVE-2021-20588 | 1 Mitsubishielectric | 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more | 2024-11-21 | 9.8 Critical |
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. | ||||
CVE-2021-20587 | 1 Mitsubishielectric | 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more | 2024-11-21 | 9.8 Critical |
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. | ||||
CVE-2021-20586 | 1 Mitsubishielectric | 66 Rh12frh55, Rh12frh55 Firmware, Rh12frh85 and 63 more | 2024-11-21 | 7.5 High |
Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs. | ||||
CVE-2020-5675 | 1 Mitsubishielectric | 20 Gs2107-wtbd, Gs2107-wtbd-n, Gs2107-wtbd-n Firmware and 17 more | 2024-11-21 | 7.5 High |
Out-of-bounds read vulnerability in GT21 model of GOT2000 series (GT2107-WTBD V01.39.000 and earlier, GT2107-WTSD V01.39.000 and earlier, GT2104-RTBD V01.39.000 and earlier, GT2104-PMBD V01.39.000 and earlier, and GT2103-PMBD V01.39.000 and earlier), GS21 model of GOT series (GS2110-WTBD V01.39.000 and earlier, GS2107-WTBD V01.39.000 and earlier, GS2110-WTBD-N V01.39.000 and earlier, and GS2107-WTBD-N V01.39.000 and earlier), and Tension Controller LE7-40GU-L series (LE7-40GU-L Screen package data for CC-Link IEF Basic V1.00, LE7-40GU-L Screen package data for MODBUS/TCP V1.00, and LE7-40GU-L Screen package data for SLMP V1.00) allows a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted packet. As a result, deterioration of communication performance or a denial-of-service (DoS) condition of the TCP communication functions of the products may occur. | ||||
CVE-2020-5668 | 1 Mitsubishielectric | 56 R00cpu, R00cpu Firmware, R01cpu and 53 more | 2024-11-21 | 7.5 High |
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules (R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 (EN) CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier, R08/16/32/120PSFCPU firmware version '06' and earlier, RJ71EN71 firmware version '47' and earlier, RJ71GF11-T2 firmware version '47' and earlier, RJ72GF15-T2 firmware version '07' and earlier, RJ71GP21-SX firmware version '47' and earlier, RJ71GP21S-SX firmware version '47' and earlier, and RJ71GN11-T2 firmware version '11' and earlier) allows a remote unauthenticated attacker to cause an error in a CPU unit and cause a denial-of-service (DoS) condition in execution of the program and its communication, or to cause a denial-of-service (DoS) condition in communication via the unit by receiving a specially crafted SLMP packet | ||||
CVE-2020-5666 | 1 Mitsubishielectric | 16 Melsec Iq-r00, Melsec Iq-r00 Firmware, Melsec Iq-r01 and 13 more | 2024-11-21 | 7.5 High |
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series CPU Modules (R00/01/02CPU Firmware versions from '05' to '19' and R04/08/16/32/120(EN)CPU Firmware versions from '35' to '51') allows a remote attacker to cause an error in a CPU unit via a specially crafted HTTP packet, which may lead to a denial-of-service (DoS) condition in execution of the program and its communication. | ||||
CVE-2020-5665 | 1 Mitsubishielectric | 2 Melsec Iq-f Fx5u Cpu, Melsec Iq-f Fx5u Cpu Firmware | 2024-11-21 | 7.4 High |
Improper check or handling of exceptional conditions in MELSEC iQ-F series FX5U(C) CPU unit firmware version 1.060 and earlier allows an attacker to cause a denial-of-service (DoS) condition on program execution and communication by sending a specially crafted ARP packet. | ||||
CVE-2020-5658 | 1 Mitsubishielectric | 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more | 2024-11-21 | 7.5 High |
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet. | ||||
CVE-2020-5657 | 1 Mitsubishielectric | 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more | 2024-11-21 | 6.5 Medium |
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet. | ||||
CVE-2020-5656 | 1 Mitsubishielectric | 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more | 2024-11-21 | 9.8 Critical |
Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. | ||||
CVE-2020-5655 | 1 Mitsubishielectric | 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more | 2024-11-21 | 7.5 High |
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet. |