Filtered by vendor Schneider-electric
Subscriptions
Total
762 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-43376 | 1 Schneider-electric | 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more | 2024-11-21 | 7.6 High |
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulation when malicious code is inserted into the browser. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) | ||||
CVE-2022-42973 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2024-11-21 | 7.8 High |
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-42972 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2024-11-21 | 7.8 High |
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-42971 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2024-11-21 | 9.8 Critical |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-42970 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2024-11-21 | 9.8 Critical |
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
CVE-2022-41671 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-41670 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-41669 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-41668 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-41667 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-41666 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | 7 High |
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). | ||||
CVE-2022-37302 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 5.5 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior). | ||||
CVE-2022-37301 | 1 Schneider-electric | 96 Modicon M340 Bmx P34-2010, Modicon M340 Bmx P34-2010 Firmware, Modicon M340 Bmx P34-2030 and 93 more | 2024-11-21 | 7.5 High |
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior) | ||||
CVE-2022-37300 | 1 Schneider-electric | 70 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 67 more | 2024-11-21 | 9.8 Critical |
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior). | ||||
CVE-2022-34765 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.5 Medium |
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34764 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34763 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34762 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34761 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 7.5 High |
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34760 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 7.5 High |
A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) |