Filtered by vendor Tendacn Subscriptions
Total 149 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-45658 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function.
CVE-2022-45653 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function.
CVE-2022-45661 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function.
CVE-2022-45654 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2022-45660 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function.
CVE-2022-45659 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2022-45652 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function.
CVE-2022-45657 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function.
CVE-2022-45655 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
CVE-2022-45656 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function.
CVE-2022-45644 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function.
CVE-2022-45645 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function.
CVE-2022-45651 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function.
CVE-2022-45649 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function.
CVE-2022-45646 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function.
CVE-2022-45647 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function.
CVE-2022-45648 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the devName parameter in the formSetDeviceName function.
CVE-2022-45643 1 Tendacn 2 Ac6, Ac6 Firmware 2024-08-03 7.5 High
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2022-40869 1 Tendacn 4 Ac15, Ac15 Firmware, Ac18 and 1 more 2024-08-03 9.8 Critical
Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list*" ("%s%d","list").
CVE-2022-40864 1 Tendacn 4 Ac15, Ac15 Firmware, Ac18 and 1 more 2024-08-03 9.8 Critical
Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet