CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data. |
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
|
This vulnerability enables ssh access to minikube container using a default password. |
Use of Hard-coded Password in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet. |
The password for access to the debugging console of the PoWer Controller chip (PWC) of the MIB3 infotainment is hard-coded in the firmware. The console allows attackers with physical access to the MIB3 unit to gain full control over the PWC chip.
Vulnerability found on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022. |
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability, which was classified as critical, has been found in taoeffect Empress. Affected by this issue is some unknown functionality. The manipulation leads to use of hard-coded password. The patch is identified as 557e177d8a309d6f0f26de46efb38d43e000852d. It is recommended to apply a patch to fix this issue. VDB-217154 is the identifier assigned to this vulnerability. |
A vulnerability classified as critical has been found in Netis Netcore Router. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The identifier VDB-217593 was assigned to this vulnerability. |
D-Link DCS-8300LHV2 ONVIF Hardcoded PIN Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DCS-8300LHV2 IP cameras. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the ONVIF API. The issue results from the use of a hardcoded PIN. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-21492. |
A vulnerability was found in Intelligent Apps Freenow App 12.10.0 on Android. It has been rated as problematic. Affected by this issue is some unknown functionality of the file ch/qos/logback/core/net/ssl/SSL.java of the component Keystore Handler. The manipulation of the argument DEFAULT_KEYSTORE_PASSWORD with the input changeit leads to use of hard-coded password. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability, which was classified as problematic, has been found in cnoa OA up to 5.1.1.5. Affected by this issue is some unknown functionality of the file /index.php?app=main&func=passport&action=login. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-229376. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability was found in TOTOLINK LR1200 9.3.1cu.2832. It has been classified as problematic. This affects an unknown part of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272787. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability was found in TOTOLINK A3000RU 5.9c.5185. It has been rated as problematic. This issue affects some unknown processing of the file /web_cste/cgi-bin/product.ini. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272591. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been rated as critical. This issue affects some unknown processing of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier VDB-272573 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
mySCADA myPRO
uses a hard-coded password which could allow an attacker to remotely execute code on the affected device. |
AdTran 834-5 HDC17600021F1 (SmartOS 11.1.1.1) devices enable the SSH service by default and have a hidden, undocumented, hard-coded support account whose password is based on the devices MAC address. All of the devices internet interfaces share a similar MAC address that only varies in their final octet. This allows network-adjacent attackers to derive the support user's SSH password by decrementing the final octet of the connected gateway address or via the BSSID. An attacker can then execute arbitrary OS commands with root-level privileges. NOTE: The vendor states that there is no intended functionality allowing an attacker to execute arbitrary OS Commands with root-level privileges. The vendor also states that this issue was fixed in SmartOS 12.5.5.1. |
Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions. |
The LoMag WareHouse Management application version 1.0.20.120 and older were to utilize hard-coded passwords by default for forms and SQL connections. |
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements. |