| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper link resolution before file access ('link following') in Windows Routing and Remote Access Service (RRAS) allows an authorized attacker to deny service locally. |
| CSLA .NET is a framework designed for the development of reusable, object-oriented business layers for applications. Versions 5.5.4 and below allow the use of WcfProxy. WcfProxy uses the now-obsolete NetDataContractSerializer (NDCS) and is vulnerable to remote code execution during deserialization. This vulnerability is fixed in version 6.0.0. To workaround this issue, remove the WcfProxy in data portal configurations. |
| Android App "Brother iPrint&Scan" versions 6.13.7 and earlier improperly uses an external cache directory. If exploited, application-specific files may be accessed from other malicious applications. |
| Due to an Information Disclosure vulnerability in Application Server ABAP, an authenticated attacker could read unmasked values displayed in ABAP Lists. Successful exploitation could lead to unauthorized disclosure of data, resulting in a high impact on confidentiality without affecting integrity or availability. |
| Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| ParcelMismatch vulnerability in attribute deserialization.
Impact: Successful exploitation of this vulnerability may cause playback control screen display exceptions. |
| An exposure of sensitive information vulnerability has been reported to affect QNAP AI Core. If exploited, the vulnerability could allow remote attackers to compromise the security of the system.
We have already fixed the vulnerability in the following version:
QNAP AI Core 3.4.1 and later |
| A link following vulnerability has been reported to affect QuLog Center. If exploited, the vulnerability could allow remote attackers to traverse the file system to unintended locations and read or overwrite the contents of unexpected files.
We have already fixed the vulnerability in the following versions:
QuLog Center 1.7.0.831 ( 2024/10/15 ) and later
QuLog Center 1.8.0.888 ( 2024/10/15 ) and later |
| UNA CMS versions 9.0.0-RC1 - 14.0.0-RC4 contain a PHP object injection vulnerability in BxBaseMenuSetAclLevel.php where the profile_id POST parameter is passed to PHP unserialize() without proper handling, allowing remote, unauthenticated attackers to inject arbitrary PHP objects and potentially write and execute arbitrary PHP code. |
| Waveshare RS232/485 TO WIFI ETH (B) Serial to Ethernet/Wi-Fi Gateway Firmware V3.1.1.0: HW 4.3.2.1: Webpage V7.04T.07.002880.0301 was discovered to render the Administrator password in plaintext. |
| ReQuest Serious Play F3 Media Server versions 7.0.3.4968 (Pro), 7.0.2.4954, 6.5.2.4954, 6.4.2.4681, 6.3.2.4203, and 2.0.1.823 allows unauthenticated attackers to disclose the webserver's Python debug log file containing system information, credentials, paths, processes and command arguments running on the device. Attackers can access sensitive information by visiting the message_log page. |
| A privilege escalation vulnerability was identified in GitHub Enterprise Server that allowed an authenticated Enterprise admin to gain root SSH access to the appliance by exploiting a symlink escape in pre-receive hook environments. By crafting a malicious repository and environment, an attacker could replace system binaries during hook cleanup and execute a payload that adds their own SSH key to the root user’s authorized keys—thereby granting themselves root SSH access to the server. To exploit this vulnerability, the attacker needed to have enterprise admin privileges. This vulnerability affected all versions of GitHub Enterprise Server prior to 3.19, and was fixed in versions 3.14.20, 3.15.15, 3.16.11, 3.17.8, 3.18.2. This vulnerability was reported via the GitHub Bug Bounty program. |
| Login credentials are inadvertently recorded in logs if a Syslog Server is configured in NETGEAR WAX610
and WAX610Y (AX1800 Dual Band PoE Multi-Gig Insight Managed WiFi 6
Access Points). An user having access to the syslog server can read the logs containing these credentials.
This issue affects WAX610: before 10.8.11.4; WAX610Y: before 10.8.11.4.
Devices
managed with Insight get automatic updates. If not, please check the firmware version
and update to the latest.
Fixed in:
WAX610 firmware
11.8.0.10 or later.
WAX610Y firmware
11.8.0.10 or later. |
| cryptidy through 1.2.4 allows code execution via untrusted data because pickle.loads is used. This occurs in aes_decrypt_message in symmetric_encryption.py. |
| An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. They run an SSH server accessible over the default port 22. The root account has a weak default password of ionadmin, and a password change policy for the root account is not enforced. Thus, an attacker with network connectivity can achieve root code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| Symfony 1 is a community-driven fork of the 1.x branch of Symfony, a PHP framework for web projects. Starting in version 1.1.0 and prior to version 1.5.19, Symfony 1 has a gadget chain due to dangerous deserialization in `sfNamespacedParameterHolder` class that would enable an attacker to get remote code execution if a developer deserializes user input in their project. Version 1.5.19 contains a patch for the issue. |
| Symfony1 is a community fork of symfony 1.4 with DIC, form enhancements, latest Swiftmailer, better performance, composer compatible and PHP 8 support. Symfony 1 has a gadget chain due to vulnerable Swift Mailer dependency that would enable an attacker to get remote code execution if a developer unserialize user input in his project. This vulnerability present no direct threat but is a vector that will enable remote code execution if a developper deserialize user untrusted data. Symfony 1 depends on Swift Mailer which is bundled by default in vendor directory in the default installation since 1.3.0. Swift Mailer classes implement some `__destruct()` methods. These methods are called when php destroys the object in memory. However, it is possible to include any object type in `$this->_keys` to make PHP access to another array/object properties than intended by the developer. In particular, it is possible to abuse the array access which is triggered on foreach($this->_keys ...) for any class implementing ArrayAccess interface. This may allow an attacker to execute any PHP command which leads to remote code execution. This issue has been addressed in version 1.5.18. Users are advised to upgrade. There are no known workarounds for this vulnerability. |