Search vulnerabilities

Results 2,380

CVE-2012-3003

Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.

CVSS 2.0 · 5.8 Medium EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2012-4693

Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file.

CVSS 2.0 · 1.9 Low EPSS < 1% KEV · Not listed
Vendors
CVE-2011-4532

Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.

CVSS 2.0 · 5.0 Medium EPSS 3.2% KEV · Not listed
Vendors
CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.

CVSS 2.0 · 7.8 High EPSS 11.1% KEV · Not listed
Vendors
CVE-2013-0677

The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.

CVSS 2.0 · 5.8 Medium EPSS 1.9% KEV · Not listed
Vendors
Products
CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.

CVSS 2.0 · 7.1 High EPSS 7.3% KEV · Not listed
Vendors
CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.

CVSS 2.0 · 9.3 Critical EPSS 9.0% KEV · Not listed
Vendors
CVE-2013-3958

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.

CVSS 2.0 · 7.5 High EPSS 1.9% KEV · Not listed
Vendors
Products
CVE-2013-0672

Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.

CVSS 2.0 · 3.5 Low EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2013-0671

Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.

CVSS 2.0 · 4.0 Medium EPSS 2.3% KEV · Not listed
Vendors
Products
CVE-2012-1800

Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.

CVSS 2.0 · 6.1 Medium EPSS 1.6% KEV · Not listed
Vendors
CVE-2013-0670

CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.

CVSS 2.0 · 4.3 Medium EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2011-4055

Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.

CVSS 2.0 · 9.3 Critical EPSS 4.6% KEV · Not listed
Vendors
CVE-2012-2441

RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.

CVSS 2.0 · 8.5 High EPSS 8.5% KEV · Not listed
Vendors
CVE-2011-4512

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.

CVSS 2.0 · 5.0 Medium EPSS 1.6% KEV · Not listed
Vendors
CVE-2011-4508

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.

CVSS 2.0 · 9.3 Critical EPSS 3.0% KEV · Not listed
Vendors
CVE-2011-4511

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.

CVSS 2.0 · 4.3 Medium EPSS 1.4% KEV · Not listed
Vendors
CVE-2012-3032

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

CVSS 2.0 · 7.5 High EPSS 2.4% KEV · Not listed
Vendors
Products
CVE-2013-0669

The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.

CVSS 2.0 · 4.0 Medium EPSS 1.8% KEV · Not listed
Vendors
Products