| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability was discovered in Samsung Mobile Processor Exynos 850, Exynos 9610, Exynos 980, Exynos 1280, Exynos 1380, Exynos 1330, Exynos W920, and Exynos W930 where it does not properly check a pointer address, which can lead to a Information disclosure. |
| An issue in INATRONIC com.inatronic.bmw 2.7.1 allows a remote attacker to obtain sensitive information via the firmware update process. |
| An issue in Creative Labs Pte Ltd com.creative.apps.xficonnect 2.00.02 allows a remote attacker to obtain sensitive information via the firmware update process. |
| An issue in EQUES com.eques.plug 1.0.1 allows a remote attacker to obtain sensitive information via the firmware update process. |
| Privilege escalation in Automatic Systems Maintenance SlimLane 29565_d74ecce0c1081d50546db573a499941b10799fb7 allows a remote attacker to escalate privileges via the FtpConfig.php page. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| An escalation of privilege vulnerability in ASPECT could provide an attacker root access to a server when logged in as a "non" root ASPECT user. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign. |
| An unauthenticated attacker can perform an out of bounds heap read in the IQ Service (TCP port 9876). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111. |
| In One Identity Identity Manager 9.x before 9.3, an insecure direct object reference (IDOR) vulnerability allows privilege escalation. Only On-Premise installations are affected. |
| A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper physical access control. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. |
| Improper Control of Generation of Code ('Code Injection') vulnerability in Codeer Limited Bricks Builder allows Code Injection.This issue affects Bricks Builder: from n/a through 1.9.6. |
| A vulnerability has been found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This vulnerability affects unknown code of the component Backend IPC Server. The manipulation leads to denial of service. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability was identified in INSTAR 2K+ and 4K 3.11.1 Build 1124. This affects the function base64_decode of the component fcgi_server. The manipulation of the argument Authorization leads to buffer overflow. It is possible to initiate the attack remotely. |
| Incorrect access control in the firmware update and download processes of DreamCatcher Life v1.8.7 allows attackers to access sensitive information by analyzing the code and data within the APK file. |
| Incorrect access control in the firmware update and download processes of Sylvania Smart Home v3.0.3 allows attackers to access sensitive information by analyzing the code and data within the APK file. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| An issue in Hangzhou Bobo Technology Co Ltd UU Game Booster iOS 10.6.13 allows attackers to access sensitive user information via supplying a crafted link. |
| An attacker can publish a zone containing specific Resource Record Sets.
Repeatedly processing and caching results for these sets can lead to a
denial of service. |