| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function. |
| A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory. |
| Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device. |
| Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. |
| Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. |
| Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. |
| Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. |
| Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. |
| Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. |
| Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. |
| Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. |
| Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. |
| Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg. |
| Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter. |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind. |