| The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N. |
| Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. |
| In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access. |
| In ovirt-engine 4.1, if a host was provisioned with cloud-init, the root password could be revealed through the REST interface. |
| Platform sample code firmware included with 4th Gen Intel Core Processor, 5th Gen Intel Core Processor, 6th Gen Intel Core Processor, and 7th Gen Intel Core Processor potentially exposes password information in memory to a local attacker with administrative privileges. |
| NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance. |
| A BIOS password extraction vulnerability has been reported on certain consumer notebooks with firmware F.22 and others. The BIOS password was stored in CMOS in a way that allowed it to be extracted. This applies to consumer notebooks launched in early 2014. |
| The skyring-setup command creates random password for mongodb skyring database but it writes password in plain text to /etc/skyring/skyring.conf file which is owned by root but read by local user. Any local user who has access to system running skyring service will be able to get password in plain text. |
| IBM Cognos Analytics 11.0 could store cached credentials locally that could be obtained by a local user. IBM X-Force ID: 136824. |
| IBM Cognos Business Intelligence 10.2, 10.2.1, 10.2.1.1, and 10.2.2, under specialized circumstances, could expose plain text credentials to a local user. IBM X-Force ID: 136149. |
| IBM Security Identity Governance Virtual Appliance 5.2 through 5.2.3.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 127399. |
| IBM BigFix Platform 9.5 - 9.5.9 stores user credentials in plain in clear text which can be read by a local user. IBM X-Force ID: 123910. |
| Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects R6700v2 before 1.1.0.38 and R6800 before 1.1.0.38. |
| Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects R6700v2 before 1.1.0.38, R6800 before 1.1.0.38, and D7000 before 1.0.1.50. |
| Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects R6700v2 before 1.1.0.38, R6800 before 1.1.0.38, and D7000 before 1.0.1.50. |
| Certain NETGEAR devices are affected by administrative password disclosure. This affects D6220 before V1.0.0.28, D6400 before V1.0.0.60, D8500 before V1.0.3.29, DGN2200v4 before 1.0.0.82, DGN2200Bv4 before 1.0.0.82, R6300v2 before 1.0.4.8, R6400 before 1.0.1.20, R6700 before 1.0.1.20, R6900 before 1.0.1.20, R7000 before 1.0.7.10, R7100LG before V1.0.0.32, R7300DST before 1.0.0.52, R7900 before 1.0.1.16, R8000 before 1.0.3.36, R8300 before 1.0.2.94, R8500 before 1.0.2.94, WNDR3400v3 before 1.0.1.12, and WNR3500Lv2 before 1.2.0.40. |
| An issue was discovered on Samsung mobile devices with KK(4.4), L(5.0/5.1), M(6.0), and N(7.0) software. Attackers (who control a certain subdomain) can discover a user's credentials, during an email account login, via an EAS autodiscover packet. The Samsung ID is SVE-2016-7654 (January 2017). |
| Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack. |
| Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password. The encryption uses a fixed key, that could be extracted by an attacker. Precondition of the exploitation of this weakness is network access at the moment a route is added. |
| In Ice Qube Thermal Management Center versions prior to version 4.13, passwords are stored in plaintext in a file that is accessible without authentication. |