Filtered by vendor Siemens Subscriptions
Total 1927 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-19299 1 Siemens 1 Sinvr\/sivms Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server applies weak cryptography when exposing device (camera) passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks.
CVE-2019-19298 1 Siemens 1 Sinvr\/sivms Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requests.
CVE-2019-19297 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a path traversal vulnerability, that could allow an unauthenticated remote attacker to access and download arbitrary files from the server.
CVE-2019-19296 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 6.8 Medium
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video Server contain a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server, if the FTP services are enabled.
CVE-2019-19295 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 4.3 Medium
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log.
CVE-2019-19294 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 6.3 Medium
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains multiple stored Cross-site Scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content.
CVE-2019-19293 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 6.1 Medium
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a reflected Cross-site Scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator of the CCS web interface.
CVE-2019-19292 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 8.8 High
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.
CVE-2019-19291 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 5.3 Medium
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0). The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server (CCS) maintain log files that store login credentials in cleartext. In configurations where the FTP service is enabled, authenticated remote attackers could extract login credentials of other users of the service.
CVE-2019-19290 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 6.5 Medium
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center Server (CCS) contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed.
CVE-2019-19289 1 Siemens 1 Xhq 2024-11-21 8.8 High
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link.
CVE-2019-19288 1 Siemens 1 Xhq 2024-11-21 6.1 Medium
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
CVE-2019-19287 1 Siemens 1 Xhq 2024-11-21 6.5 Medium
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow attackers to traverse through the file system of the server based by sending specially crafted packets over the network without authentication.
CVE-2019-19286 1 Siemens 1 Xhq 2024-11-21 7.2 High
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow SQL injection attacks if an attacker is able to modify content of particular web pages.
CVE-2019-19285 1 Siemens 1 Xhq 2024-11-21 5.4 Medium
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow injections that could lead to XSS attacks if unsuspecting users are tricked into accessing a malicious link.
CVE-2019-19284 1 Siemens 1 Xhq 2024-11-21 5.4 Medium
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users.
CVE-2019-19283 1 Siemens 1 Xhq 2024-11-21 5.3 Medium
A vulnerability has been identified in XHQ (All Versions < 6.1). The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place.
CVE-2019-19282 1 Siemens 6 Openpcs 7, Simatic Batch, Simatic Net Pc and 3 more 2024-11-21 7.5 High
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
CVE-2019-19281 1 Siemens 28 Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware, Simatic S7-1500 Cpu 1507s and 25 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V2.5 and < V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 and < V2.8), SIMATIC S7-1500 Software Controller (All versions >= V2.5 and < V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability.
CVE-2019-19279 1 Siemens 2 Siprotec 4, Siprotec Compact 2024-11-21 7.5 High
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.