Filtered by vendor Siemens Subscriptions
Total 1847 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-47967 1 Siemens 1 Solid Edge 2024-08-03 7.8 High
A vulnerability has been identified in Solid Edge (All versions < V2023 MP1). The DOCMGMT.DLL contains a memory corruption vulnerability that could be triggered while parsing files in different file formats such as PAR, ASM, DFT. This could allow an attacker to execute code in the context of the current process.
CVE-2022-47935 1 Siemens 3 Jt Open Toolkit, Jt Utilities, Solid Edge 2024-08-03 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a memory corruption vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19078)
CVE-2022-47936 1 Siemens 3 Jt Open Toolkit, Jt Utilities, Parasolid 2024-08-03 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
CVE-2022-47375 1 Siemens 18 6ag1414-3em07-7ab0, 6ag1414-3em07-7ab0 Firmware, 6ag1416-3es07-7ab0 and 15 more 2024-08-03 7.5 High
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
CVE-2022-47374 1 Siemens 18 6ag1414-3em07-7ab0, 6ag1414-3em07-7ab0 Firmware, 6ag1416-3es07-7ab0 and 15 more 2024-08-03 7.5 High
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
CVE-2022-46664 1 Siemens 1 Mendix Workflow Commons 2024-08-03 8.1 High
A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read or delete sensitive information.
CVE-2022-46355 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 7.5 High
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The affected products are vulnerable to an "Exposure of Sensitive Information to an Unauthorized Actor" vulnerability by leaking sensitive data in the HTTP Referer.
CVE-2022-46348 1 Siemens 1 Parasolid 2024-08-03 7.8 High
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)
CVE-2022-46345 1 Siemens 3 Parasolid, Solid Edge Se2022, Solid Edge Se2023 2024-08-03 7.8 High
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)
CVE-2022-46349 1 Siemens 1 Parasolid 2024-08-03 7.8 High
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)
CVE-2022-46351 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 5.5 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2).
CVE-2022-46353 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 9.8 Critical
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
CVE-2022-46352 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 7.5 High
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products.
CVE-2022-46350 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 6.1 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
CVE-2022-46346 1 Siemens 3 Parasolid, Solid Edge Se2022, Solid Edge Se2023 2024-08-03 7.8 High
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)
CVE-2022-46354 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2024-08-03 5.3 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
CVE-2022-46347 1 Siemens 1 Parasolid 2024-08-03 7.8 High
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)
CVE-2022-46265 1 Siemens 1 Polarion Alm 2024-08-03 5.4 Medium
A vulnerability has been identified in Polarion ALM (All versions < V2304.0). The affected application contains a Host header injection vulnerability that could allow an attacker to spoof a Host header information and redirect users to malicious websites.
CVE-2022-46142 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2024-08-03 5.7 Medium
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
CVE-2022-46140 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2024-08-03 6.5 Medium
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.