CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
An issue was discovered in the MensaMax (aka com.breustedt.mensamax) application 4.3 for Android. The use of a Hard-coded DES Cryptographic Key allows an attacker who decodes the application to decrypt transmitted data such as the login username and password. |
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API. |
A vulnerability in the permission and encryption implementation of Zemana Anti-Logger 1.9.3.527 and prior (fixed in 1.9.3.602) allows an attacker to take control of the whitelisting feature (MyRules2.ini under %LOCALAPPDATA%\Zemana\ZALSDK) to permit execution of unauthorized applications (such as ones that record keystrokes). |
An attacker without authentication can login with default credentials for privileged users in Eltex ESP-200 firmware version 1.2.0. |
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account. |
The EPSON iPrint application 6.6.3 for Android contains hard-coded API and Secret keys for the Dropbox, Box, Evernote and OneDrive services. |
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords. |
Invoxia NVX220 devices allow TELNET access as admin with a default password. |
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product. |
A hardcoded passphrase, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information. |
A hardcoded secret key, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information. |
The server API in the Anda app relies on hardcoded credentials. |
Sollae Serial-Ethernet-Module and Remote-I/O-Device-Server devices have a default password of sollae for the TELNET service. |
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password. |
Telesquare SDT-CS3B1 and SDT-CW3B1 devices through 1.2.0 have a default factory account. Remote attackers can obtain access to the device via TELNET using a hardcoded account. |
An issue was discovered on Momentum Axel 720P 5.1.8 devices. A password of EHLGVG is hard-coded for the root and admin accounts, which makes it easier for physically proximate attackers to login at the console. |
The Norton Identity Safe product prior to 5.3.0.976 may be susceptible to a privilege escalation issue via a hard coded IV, which is a type of vulnerability that can potentially increase the likelihood of encrypted data being recovered without adequate credentials. |
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool. |
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine |
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine |