Filtered by vendor Siemens
Subscriptions
Total
1927 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2019-12262 | 3 Belden, Siemens, Windriver | 42 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 39 more | 2024-11-21 | 9.8 Critical |
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw). | ||||
CVE-2019-12261 | 6 Belden, Netapp, Oracle and 3 more | 51 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 48 more | 2024-11-21 | 9.8 Critical |
Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host. | ||||
CVE-2019-12260 | 6 Belden, Netapp, Oracle and 3 more | 51 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 48 more | 2024-11-21 | 9.8 Critical |
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option. | ||||
CVE-2019-12259 | 4 Belden, Siemens, Sonicwall and 1 more | 49 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 46 more | 2024-11-21 | 7.5 High |
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing. | ||||
CVE-2019-12258 | 5 Belden, Netapp, Siemens and 2 more | 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more | 2024-11-21 | 7.5 High |
Wind River VxWorks 6.6 through vx7 has Session Fixation in the TCP component. This is a IPNET security vulnerability: DoS of TCP connection via malformed TCP options. | ||||
CVE-2019-12257 | 5 Belden, Netapp, Siemens and 2 more | 46 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 43 more | 2024-11-21 | 8.8 High |
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc. | ||||
CVE-2019-12256 | 5 Belden, Netapp, Siemens and 2 more | 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more | 2024-11-21 | 9.8 Critical |
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options. | ||||
CVE-2019-12255 | 5 Belden, Netapp, Siemens and 2 more | 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more | 2024-11-21 | 9.8 Critical |
Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow. | ||||
CVE-2019-11745 | 6 Canonical, Debian, Mozilla and 3 more | 29 Ubuntu Linux, Debian Linux, Firefox and 26 more | 2024-11-21 | 8.8 High |
When encrypting with a block cipher, if a call to NSC_EncryptUpdate was made with data smaller than the block size, a small out of bounds write could occur. This could have caused heap corruption and a potentially exploitable crash. This vulnerability affects Thunderbird < 68.3, Firefox ESR < 68.3, and Firefox < 71. | ||||
CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2024-11-21 | 7.5 High |
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | ||||
CVE-2019-10943 | 1 Siemens | 22 Simatic Et 200sp Open Controller Cpu 1515sp Pc, Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware and 19 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device. | ||||
CVE-2019-10942 | 1 Siemens | 6 Scalance X-200, Scalance X-200 Firmware, Scalance X-200irt and 3 more | 2024-11-21 | 8.6 High |
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. | ||||
CVE-2019-10941 | 1 Siemens | 1 Sinema Server | 2024-11-21 | 5.3 Medium |
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges. | ||||
CVE-2019-10940 | 1 Siemens | 1 Sinema Server | 2024-11-21 | 9.9 Critical |
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-10939 | 1 Siemens | 10 Tim 3v-ie, Tim 3v-ie Advanced, Tim 3v-ie Advanced Firmware and 7 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | ||||
CVE-2019-10938 | 1 Siemens | 25 6md85, 6md86, 6md89 and 22 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-10937 | 1 Siemens | 2 Simatic Tdc Cp51m1, Simatic Tdc Cp51m1 Firmware | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-10936 | 1 Siemens | 130 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 and 127 more | 2024-11-21 | 7.5 High |
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. | ||||
CVE-2019-10935 | 1 Siemens | 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime | 2024-11-21 | N/A |
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | ||||
CVE-2019-10934 | 1 Siemens | 1 Totally Integrated Automation Portal | 2024-11-21 | 7.8 High |
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. |