| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A RootCA vulnerability found in Trend Micro Password Manager for Windows and macOS exists where the localhost.key of RootCA.crt might be improperly accessed by an unauthorized party and could be used to create malicious self-signed SSL certificates, allowing an attacker to misdirect a user to phishing sites. |
| Trend Micro Mobile Security for Android (Consumer) versions 10.3.1 and below on Android 8.0+ has an issue in which an attacker could bypass the product's App Password Protection feature. |
| OpenStack Keystone 15.0.0 and 16.0.0 is affected by Data Leakage in the list credentials API. Any user with a role on a project is able to list any credentials with the /v3/credentials API when enforce_scope is false. Users with a role on a project are able to view any other users' credentials, which could (for example) leak sign-on information for Time-based One Time Passwords (TOTP). Deployments with enforce_scope set to false are affected. (There will be a slight performance impact for the list credentials API once this issue is fixed.) |
| An issue was discovered in Idelji Web ViewPoint H01ABO-H01BY and L01ABP-L01ABZ, Web ViewPoint Plus H01AAG-H01AAQ and L01AAH-L01AAR, and Web ViewPoint Enterprise H01-H01AAE and L01-L01AAF. By reading ADB or AADB file content within the Installation subvolume, a Guardian user can discover the password of the group.user or alias who acknowledges events from the WVP Events screen. |
| GitLab Enterprise Edition (EE) 9.0 and later through 12.5 allows Information Disclosure. |
| BMC Control-M/Agent 7.0.00.000 has Insecure Password Storage. |
| An issue was discovered in PRTG 7.x through 19.4.53. Due to insufficient access control on local registry keys for the Core Server Service, a non-administrative user on the local machine is able to access administrative credentials. |
| The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext. |
| The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality. |
| eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords. |
| Weak password requirements in Blaauw Remote Kiln Control through v3.00r4 allow a user to set short or guessable passwords (e.g., 1 or 1234). |
| Blaauw Remote Kiln Control through v3.00r4 allows an unauthenticated attacker to access MySQL credentials in cleartext in /engine/db.inc, /lang/nl.bak, or /lang/en.bak. |
| Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password. |
| SuiteCRM 7.10.x prior to 7.10.21 and 7.11.x prior to 7.11.9 mishandles API access tokens and credentials. |
| In CloudVision Portal (CVP) for all releases in the 2018.2 Train, under certain conditions, the application logs user passwords in plain text for certain API calls, potentially leading to user password exposure. This only affects CVP environments where: 1. Devices have enable mode passwords which are different from the user's login password, OR 2. There are configlet builders that use the Device class and specify username and password explicitly Application logs are not accessible or visible from the CVP GUI. Application logs can only be read by authorized users with privileged access to the VM hosting the CVP application. |
| The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application. |
| BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit. |
| ThinVNC 1.0b1 is vulnerable to arbitrary file read, which leads to a compromise of the VNC server. The vulnerability exists even when authentication is turned on during the deployment of the VNC server. The password for authentication is stored in cleartext in a file that can be read via a ../../ThinVnc.ini directory traversal attack vector. |
| Jfrog Artifactory uses default passwords (such as "password") for administrative accounts and does not require users to change them. This may allow unauthorized network-based attackers to completely compromise of Jfrog Artifactory. This issue affects Jfrog Artifactory versions prior to 6.17.0. |
| The Customer's Tomedo Server in Version 1.7.3 communicates to the Vendor Tomedo Server via HTTP (in cleartext) that can be sniffed by unauthorized actors. Basic authentication is used for the authentication, making it possible to base64 decode the sniffed credentials and discover the username and password. |