Search Results (2021 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-43765 1 Br-automation 1 Industrial Automation Aprol 2025-03-25 7.5 High
B&R APROL versions < R 4.2-07 doesn’t process correctly specially formatted data packages sent to port 55502/tcp, which may allow a network based attacker to cause an application Denial-of-Service.
CVE-2025-30106 2025-03-21 8.8 High
On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing.
CVE-2025-2555 2025-03-20 2.9 Low
A vulnerability classified as problematic has been found in Audi Universal Traffic Recorder App 2.0. Affected is an unknown function of the component FTP Credentials. The manipulation leads to use of hard-coded password. Attacking locally is a requirement. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2025-2556 2025-03-20 4.3 Medium
A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2023-23003 1 Linux 1 Linux Kernel 2025-03-20 4 Medium
In the Linux kernel before 5.16, tools/perf/util/expr.c lacks a check for the hashmap__new return value.
CVE-2025-25727 2025-03-19 6.2 Medium
Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext.
CVE-2023-23004 1 Linux 1 Linux Kernel 2025-03-19 5.5 Medium
In the Linux kernel before 5.19, drivers/gpu/drm/arm/malidp_planes.c misinterprets the get_sg_table return value (expects it to be NULL in the error case, whereas it is actually an error pointer).
CVE-2023-23005 2 Linux, Suse 2 Linux Kernel, Linux Enterprise Server 2025-03-19 5.5 Medium
In the Linux kernel before 6.2, mm/memory-tiers.c misinterprets the alloc_memory_type return value (expects it to be NULL in the error case, whereas it is actually an error pointer). NOTE: this is disputed by third parties because there are no realistic cases in which a user can cause the alloc_memory_type error case to be reached.
CVE-2021-37000 1 Huawei 1 Harmonyos 2025-03-18 7.7 High
Some Huawei wearables have a permission management vulnerability.
CVE-2025-2322 2025-03-18 7.3 High
A vulnerability was found in 274056675 springboot-openai-chatgpt e84f6f5. It has been classified as critical. This affects an unknown part of the file /chatgpt-boot/src/main/java/org/springblade/modules/mjkj/controller/OpenController.java. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This product does not use versioning. This is why information about affected and unaffected releases are unavailable. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-20999 1 Oracle 2 Solaris, Solaris Operating System 2025-03-17 8.2 High
Vulnerability in the Oracle Solaris product of Oracle Systems (component: Zones). The supported version that is affected is 11. Easily exploitable vulnerability allows high privileged attacker with logon to the infrastructure where Oracle Solaris executes to compromise Oracle Solaris. While the vulnerability is in Oracle Solaris, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in takeover of Oracle Solaris. CVSS 3.1 Base Score 8.2 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).
CVE-2025-2342 2025-03-17 5.3 Medium
A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-2343 2025-03-17 7.5 High
A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-2355 2025-03-17 3.3 Low
A vulnerability was found in BlackVue App 3.65 on Android and classified as problematic. Affected by this issue is some unknown functionality of the component API Endpoint Handler. The manipulation of the argument BCS_TOKEN/SECRET_KEY leads to unprotected storage of credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-25024 1 Ibm 2 Cloud Pak For Security, Qradar Suite 2025-03-13 5.5 Medium
IBM QRadar Suite Software 1.10.12.0 through 1.10.23.0 and IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 stores user credentials in plain clear text which can be read by a local user. IBM X-Force ID: 281430.
CVE-2023-50945 3 Ibm, Linux, Microsoft 4 Aix, Common Licensing, Linux Kernel and 1 more 2025-03-11 6.2 Medium
IBM Common Licensing 9.0 stores user credentials in plain clear text which can be read by a local user.
CVE-2024-43653 2025-03-11 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2025-03-11 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2025-03-11 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43650 2025-03-11 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).