| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Shell Metacharacter Injection in www/modules/save.php in FruityWifi (aka PatatasFritas/PatataWifi) through 2.4 allows remote attackers to execute arbitrary code with root privileges via a crafted mod_name parameter in a POST request. NOTE: unlike in CVE-2018-17317, the attacker does not need a valid session. |
| Zoho ManageEngine ADAudit before 5.1 build 5120 allows remote attackers to cause a denial of service (stack-based buffer overflow) via the 'Domain Name' field when adding a new domain. |
| keepalived before 2.0.7 has a heap-based buffer overflow when parsing HTTP status codes resulting in DoS or possibly unspecified other impact, because extract_status_code in lib/html.c has no validation of the status code and instead writes an unlimited amount of data to the heap. |
| LibreCAD 2.1.3 allows remote attackers to cause a denial of service (0x89C04589 write access violation and application crash) or possibly have unspecified other impact via a crafted file. |
| RegFilter.sys in IOBit Malware Fighter 6.2 is susceptible to a stack-based buffer overflow when an attacker uses IOCTL 0x8006E044 with a size larger than 8 bytes. This can lead to denial of service or code execution with root privileges. |
| RegFilter.sys in IOBit Malware Fighter 6.2 is susceptible to a stack-based buffer overflow when an attacker uses IOCTL 0x8006E040 with a size larger than 8 bytes. This can lead to denial of service or code execution with root privileges. |
| RegFilter.sys in IOBit Malware Fighter 6.2 is susceptible to a stack-based buffer overflow when an attacker uses IOCTL 0x8006E048 with a size larger than 8 bytes. This can lead to denial of service or code execution with root privileges. |
| RegFilter.sys in IOBit Malware Fighter 6.2 is susceptible to a stack-based buffer overflow when an attacker uses IOCTL 0x8006E05C with a size larger than 8 bytes. This can lead to denial of service or code execution with root privileges. |
| An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ONVIF devicemgmt SetDNS method allows remote attackers to conduct stack-based buffer overflow attacks via the IPv4Address field. |
| An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ONVIF devicemgmt SetDNS method allows remote attackers to execute arbitrary OS commands via the IPv4Address field. |
| An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow attackers to execute arbitrary OS commands via shell metacharacters in the modelName, by leveraging /mnt/mtd/app/config/ProductConfig.xml write access. |
| An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow remote attackers to execute arbitrary OS commands via shell metacharacters in the usrName parameter of a CGIProxy.fcgi addAccount action. |
| An attacker could inject commands to launch programs and create, write, and read files on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file. An attacker could exploit this to execute code under the privileges of the application. |
| In Geutebrueck GmbH E2 Camera Series versions prior to 1.12.0.25 the DDNS configuration (in the Network Configuration panel) is vulnerable to an OS system command injection as root. |
| WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack. |
| Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application. |
| LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution. |
| In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services. |
| An issue has been found in libIEC61850 v1.3. It is a stack-based buffer overflow in prepareGooseBuffer in goose/goose_publisher.c. |
| The pnv_lpc_do_eccb function in hw/ppc/pnv_lpc.c in Qemu before 3.1 allows out-of-bounds write or read access to PowerNV memory. |