| An attacker may be able to execute malicious actions due to the lack of device access protections and device permissions when using the web application. This could lead to uploading python files which can be later executed. |
| Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin` password. There is no warning or prompt to ask the user to change the default password, and to change the password, many steps are required. |
| The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account. |
| The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements. |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) is vulnerable to a stack-based buffer overflow, which could allow an attacker to crash the device or remotely execute arbitrary code. |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) does not sanitize input before memcpy is used, which could allow an attacker to crash the device or remotely execute arbitrary code. |
|
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.
|
|
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.
|
| Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition. |
| Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to unrestricted file uploads, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition. |
| Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the “Ethernet Q Commands” service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device. |
| Haas Controller version 100.20.000.1110 has insufficient granularity of access control when using the "Ethernet Q Commands" service. Any user is able to write macros into registers outside of the authorized accessible range. This could allow a user to access privileged resources or resources out of context. |
| Communication traffic involving "Ethernet Q Commands" service of Haas Controller version 100.20.000.1110 is transmitted in cleartext. This allows an attacker to obtain sensitive information being passed to and from the controller. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
|
|
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
|
|
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
|
|
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
|
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
|
| Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition. |
| Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system. |