| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An access control issue in the component /ManageRoute/postRoute of FreeTAKServer v1.9.8 allows unauthenticated attackers to cause a Denial of Service (DoS) via an unusually large amount of created routes, or create unsafe or false routes for legitimate users. |
| On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files. |
| Zoho ManageEngine ServiceDesk Plus before 13001 allows anyone to know the organisation's default currency name. |
| totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism. |
| Lexmark products through 2022-02-10 have Incorrect Access Control. |
| An issue was discovered in DSK DSKNet 2.16.136.0 and 2.17.136.5. It mishandles access control. This allows a remote attacker to access account information pages (including personal data) without being authenticated. The collected information includes the badge numbers that operate as user login names. They have a PIN code. The PIN code is 4 digits and thus can be guessed in 10000 brute force attempts. |
| In IOBit IOTransfer 4.3.1.1561, an unauthenticated attacker can send GET and POST requests to Airserv and gain arbitrary read/write access to the entire file-system (with admin privileges) on the victim's endpoint, which can result in data theft and remote code execution. |
| The TETRA TEA1 keystream generator implements a key register initialization function that compresses the 80-bit key to only 32 bits for usage during the keystream generation phase, which is insufficient to safeguard against exhaustive search attacks. |
| The Simple Diagnostics Agent - versions 1.0 up to version 1.57, does not perform any authentication checks for functionalities that can be accessed via localhost on http port 3005. Due to lack of authentication checks, an attacker could access administrative or other privileged functionalities and read, modify, or delete sensitive information and configurations. |
| In Mahara 21.04 before 21.04.3 and 21.10 before 21.10.1, portfolios created in groups that have not been shared with non-group members and portfolios created on the site and institution levels can be viewed without requiring a login if the URL to these portfolios is known. |
| A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The login functionality of the application does not employ any countermeasures against Password Spraying attacks or Credential Stuffing attacks. An attacker could obtain a list of valid usernames on the device by exploiting the issue and then perform a precise Password Spraying or Credential Stuffing attack in order to obtain access to at least one account. |
| Missing authentication on ShenYu Admin when register by HTTP. This issue affected Apache ShenYu 2.4.0 and 2.4.1. |
| User can access /plugin api without authentication. This issue affected Apache ShenYu 2.4.0 and 2.4.1. |
| When the device is in factory state, it can be access the shell without adb authentication process. The LG ID is LVE-SMP-210010. |
| PingID Windows Login prior to 2.8 does not authenticate communication with a local Java service used to capture security key requests. An attacker with the ability to execute code on the target machine maybe able to exploit and spoof the local Java service using multiple attack vectors. A successful attack can lead to code executed as SYSTEM by the PingID Windows Login application, or even a denial of service for offline security key authentication. |
| BigAnt Software BigAnt Server v5.6.06 was discovered to contain incorrect access control. |
| USBView 2.1 before 2.2 allows some local users (e.g., ones logged in via SSH) to execute arbitrary code as root because certain Polkit settings (e.g., allow_any=yes) for pkexec disable the authentication requirement. Code execution can, for example, use the --gtk-module option. This affects Ubuntu, Debian, and Gentoo. |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) |
| CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00. |