| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Vulnerability in AMSS++ version 4.31 that allows SQL injection through /amssplus/modules/book/main/bookdetail_khet_person.php, in multiple parameters. This vulnerability could allow a remote attacker to send a specially crafted SQL query to the server and retrieve all the information stored in the DB. |
| Vulnerability in AMSS++ version 4.31 that allows SQL injection through /amssplus/admin/index.php, in the 'id' parameter. This vulnerability could allow a remote attacker to send a specially crafted SQL query to the server and retrieve all the information stored in the DB. |
| WECON LeviStudioU Versions 2019-09-21 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code. |
| WECON LeviStudioU Versions 2019-09-21 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute code. |
| Omron CX-One Versions 4.60 and prior are vulnerable to a stack-based buffer overflow while processing specific project files, which may allow an attacker to execute arbitrary code. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. |
| Inadequate folder security permissions in Emerson OpenEnterprise versions through 3.3.4 may allow modification of important configuration files, which could cause the system to fail or behave in an unpredictable manner. |
| The affected product is vulnerable to an out-of-bounds write while processing project files, which allows an attacker to craft a project file that would allow arbitrary code execution. |
| The affected product is vulnerable to an out-of-bounds read while processing project files, which allows an attacker to craft a project file that would allow arbitrary code execution. |
| The affected product is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code |
| Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects. |
| The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system. |
| The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history. |
| The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services). |
| ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. |
| Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure. |