| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A remote attacker with write access to PI ProcessBook files could inject code that is imported into OSIsoft PI Vision 2020 versions prior to 3.5.0. Unauthorized information disclosure, modification, or deletion is also possible if a victim views or interacts with the infected display. This vulnerability affects PI System data and other data accessible with victim’s user permissions. |
| Authorized users may install a maliciously modified package file when updating the device via the web user interface. The user may inadvertently use a package file obtained from an unauthorized source or a file that was compromised between download and deployment. |
| The weak password on the web user interface can be exploited via HTTP or HTTPS. Once such access has been obtained, the other passwords can be changed. The weak password on Linux accounts can be accessed via SSH or Telnet, the former of which is by default enabled on trusted interfaces. While the SSH service does not support root login, a user logging in using either of the other Linux accounts may elevate to root access using the su command if they have access to the associated password. |
| Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page. |
| Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints. |
| Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization. |
| ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition. |
| ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition. |
| Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited |
| The affected On-Premise is vulnerable to data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate and dump all data held in the cnMaestro database. |
| The affected On-Premise cnMaestro is vulnerable to a pre-auth data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate data about other user’s accounts and devices. |
| The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks. |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. |
| The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation. |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code. |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to an out-of-bounds write condition, which may result in a system crash or allow an attacker to remotely execute arbitrary code. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| The affected product is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. |
| The affected product is vulnerable to an out-of-bounds write via uninitialized pointer, which may allow an attacker to execute arbitrary code. |
| The affected product is vulnerable to an out-of-bounds read via uninitialized pointer, which may allow an attacker to execute arbitrary code. |