| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability in the processing of SSH connections of Cisco Firepower Management Center (FMC) and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device.
This vulnerability is due to improper error handling when an SSH session fails to be established. An attacker could exploit this vulnerability by sending a high rate of crafted SSH connections to the instance. A successful exploit could allow the attacker to cause resource exhaustion, resulting in a reboot on the affected device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based management interface. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting malicious code in certain sections of the interface that are visible to other users. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. An attacker would need valid administrator credentials to exploit this vulnerability. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary code on the underlying operating system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending malicious commands to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code on the underlying operating system of the affected device. |
| A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.
This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.
This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed. |
| A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system.
The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. |
| A vulnerability in the protocol detection component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper detection of the initial use of a protocol on a nonstandard port. An attacker could exploit this vulnerability by sending traffic on a nonstandard port for the protocol in use through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. Once the initial protocol flow on the nonstandard port is detected, future flows on the nonstandard port will be successfully detected and handled as configured by the applied policy. |
| A vulnerability in the stream reassembly component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper reassembly of traffic streams. An attacker could exploit this vulnerability by sending crafted streams through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. |
| A vulnerability in the licensing service of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition.The vulnerability is due to improper handling of system resource values by the affected system. An attacker could exploit this vulnerability by sending malicious requests to the targeted system. A successful exploit could allow the attacker to cause the affected system to become unresponsive, resulting in a DoS condition and preventing the management of dependent devices. |
| A vulnerability in the multi-instance feature of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to escape the container for their Cisco FTD instance and execute commands with root privileges in the host namespace. The attacker must have valid credentials on the device.The vulnerability exists because a configuration file that is used at container startup has insufficient protections. An attacker could exploit this vulnerability by modifying a specific container configuration file on the underlying file system. A successful exploit could allow the attacker to execute commands with root privileges within the host namespace. This could allow the attacker to impact other running Cisco FTD instances or the host Cisco FXOS device. |
| A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. |
| A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to elevate privileges on an affected device. To exploit this vulnerability, an attacker must have a valid account on the device that is configured with a custom read-only role.
This vulnerability is due to insufficient validation of role permissions in part of the web-based management interface. An attacker could exploit this vulnerability by performing a write operation on the affected part of the web-based management interface. A successful exploit could allow the attacker to modify certain parts of the configuration. |
| A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software could allow an authenticated, remote attacker to conduct SQL injection attacks on an affected system.
This vulnerability exists because the web-based management interface does not validate user input adequately. An attacker could exploit this vulnerability by authenticating to the application as an Administrator and sending crafted SQL queries to an affected system. A successful exploit could allow the attacker to obtain unauthorized data from the database and make changes to the system. To exploit this vulnerability, an attacker would need Administrator-level privileges. |