A nonce reuse vulnerability exists in the ACEView service of ALEOS before 4.13.0, 4.9.5, and 4.4.9 allowing message replay. Captured traffic to the ACEView service can be replayed to other gateways sharing the same credentials. |
An authentication bypass in website post requests in the Tzumi Electronics Klic Lock application 1.0.9 for mobile devices allows attackers to access resources (that are not otherwise accessible without proper authentication) via capture-replay. Physically proximate attackers can use this information to unlock unauthorized Tzumi Electronics Klic Smart Padlock Model 5686 Firmware 6.2. |
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC. |
All versions up to V3.03.10.B23P2 of ZTE ZXR10 8905E product are impacted by TCP Initial Sequence Number (ISN) reuse vulnerability, which can generate easily predictable ISN, and allows remote attackers to spoof connections. |
It was found that cephx authentication protocol did not verify ceph clients correctly and was vulnerable to replay attack. Any attacker having access to ceph cluster network who is able to sniff packets on network can use this vulnerability to authenticate with ceph service and perform actions allowed by ceph service. Ceph branches master, mimic, luminous and jewel are believed to be vulnerable. |
In JUUKO K-808, an attacker could specially craft a packet that encodes an arbitrary command, which could be executed on the K-808 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.). |
Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state. |
All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state. |
JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running. |
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery. |
A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication (always transmitted in cleartext) can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all. |
oBike relies on Hangzhou Luoping Smart Locker to lock bicycles, which allows attackers to bypass the locking mechanism by using Bluetooth Low Energy (BLE) to replay ciphertext based on a predictable nonce used in the locking protocol. |
YSoft SafeQ Server 6 allows a replay attack. |
An issue was discovered in Descor Infocad FM before 3.1.0.0. An unauthenticated web service allows the retrieval of files on the web server and on reachable SMB servers. |
In version 1012 and prior of Insteon's Insteon Hub, the radio transmissions used for communication between the hub and connected devices are not encrypted. |
Verax NMS prior to 2.10 allows authentication via the encrypted password without knowing the cleartext password. |
Mattermost versions 9.11.x <= 9.11.2, and 9.5.x <= 9.5.10 fail to protect the mfa code against replay attacks, which allows an attacker to reuse the MFA code within ~30 seconds |
There is a privilege escalation vulnerability in ZTE ZXR10 ZSR V2 intelligent multi service router . An authenticated attacker could use the vulnerability to obtain sensitive information about the device. |
An attacker with local access to machine where MicroSCADA X
SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level
is not enabled and only users with administrator rights can enable it. |
IoT Haat Smart Plug IH-IN-16A-S v5.16.1 is vulnerable to Authentication Bypass by Capture-replay. |