Filtered by vendor Siemens
Subscriptions
Total
1927 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-27465 | 1 Siemens | 26 Simotion C240, Simotion C240 Firmware, Simotion C240 Pn and 23 more | 2024-08-02 | 4.6 Medium |
A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device. | ||||
CVE-2023-27405 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20432) | ||||
CVE-2023-27408 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2024-08-02 | 3.3 Low |
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The `i2c` mutex file is created with the permissions bits of `-rw-rw-rw-`. This file is used as a mutex for multiple applications interacting with i2c. This could allow an authenticated attacker with access to the SSH interface on the affected device to interfere with the integrity of the mutex and the data it protects. | ||||
CVE-2023-27400 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20300) | ||||
CVE-2023-27404 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20433) | ||||
CVE-2023-27410 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2024-08-02 | 2.7 Low |
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an authenticated privileged attacker to cause a denial of service. | ||||
CVE-2023-27407 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2024-08-02 | 9.9 Critical |
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The web based management of affected device does not properly validate user input, making it susceptible to command injection. This could allow an authenticated remote attacker to access the underlying operating system as the root user. | ||||
CVE-2023-27399 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20299, ZDI-CAN-20346) | ||||
CVE-2023-27401 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20308, ZDI-CAN-20345) | ||||
CVE-2023-27409 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2024-08-02 | 2.5 Low |
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file named `address`. | ||||
CVE-2023-27411 | 1 Siemens | 1 Ruggedcom Crossbow | 2024-08-02 | 8.8 High |
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges. | ||||
CVE-2023-27402 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334) | ||||
CVE-2023-27406 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449) | ||||
CVE-2023-27310 | 1 Siemens | 1 Ruggedcom Crossbow | 2024-08-02 | 6.6 Medium |
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacker to assign administrative groups to otherwise non-privileged user accounts. | ||||
CVE-2023-25910 | 1 Siemens | 3 Simatic Pcs 7, Simatic S7-pm, Simatic Step 7 | 2024-08-02 | 10 Critical |
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server. | ||||
CVE-2023-25140 | 1 Siemens | 2 Parasolid, Solid Edge | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150), Solid Edge SE2022 (All versions < V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-24989 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19811) | ||||
CVE-2023-24995 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19817) | ||||
CVE-2023-24988 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19810) | ||||
CVE-2023-24992 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-08-02 | 7.8 High |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19814) |