| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Akuvox E11 web server can be accessed without any user authentication, and this could allow an attacker to access sensitive information, as well as create and download packet captures with known default URLs. |
| The Akuvox E11 secure shell (SSH) server is enabled by default and can be accessed by the root user. This password cannot be changed by the user. |
|
Omron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program.
|
| The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states. |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. |
| Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device. |
| Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script. |
| Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts. |
| Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller. |
| Akuvox E11 appears to be using a custom version of dropbear SSH server. This server allows an insecure option that by default is not in the official dropbear SSH server. |
| The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer. |
| Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code. |
|
Instruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications.
|
|
Teltonika’s Remote Management System versions 4.14.0 is vulnerable to an unauthorized attacker registering previously unregistered devices through the RMS platform. If the user has not disabled the "RMS management feature" enabled by default, then an attacker could register that device to themselves. This could enable the attacker to perform different operations on the user's devices, including remote code execution with 'root' privileges (using the 'Task Manager' feature on RMS).
|
| Advantech R-SeeNet
versions 2.4.22
is installed with a hidden root-level user that is not available in the
users list. This hidden user has a password that cannot be changed by
users.
|
| In GeoVision GV-ADR2701 cameras, an attacker could edit the login response to access the web application.
|
|
Digi RealPort Protocol is vulnerable to a replay attack that may allow an attacker to bypass authentication to access connected equipment.
|
| ARDEREG Sistema SCADA Central versions 2.203 and prior
login page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, the vulnerability could allow an attacker to execute arbitrary SQL queries through the login page, potentially leading to unauthorized access, data leakage, or even disruption of critical industrial processes.
|
|
Dover Fueling Solutions MAGLINK LX Web Console Configuration versions 2.5.1, 2.5.2, 2.5.3, 2.6.1, 2.11, 3.0, 3.2, and 3.3 are vulnerable to authentication bypass that could allow an unauthorized attacker to obtain user access.
|