Search Results (115 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-57219 1 Tenda 1 Ac10 2025-09-01 5.3 Medium
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
CVE-2025-57218 1 Tenda 1 Ac10 2025-09-01 5.3 Medium
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
CVE-2025-57220 1 Tenda 1 Ac10 2025-09-01 5.3 Medium
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
CVE-2025-57217 1 Tenda 1 Ac10 2025-09-01 5.3 Medium
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
CVE-2025-57215 1 Tenda 1 Ac10 2025-09-01 7.5 High
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info.
CVE-2025-9309 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-25 2.5 Low
A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used.
CVE-2025-8178 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-01 8.8 High
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2018-14558 1 Tenda 6 Ac10, Ac10 Firmware, Ac7 and 3 more 2025-07-30 9.8 Critical
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
CVE-2024-33365 2 Tenda, Tendacn 3 Ac10, Ac10 Firmware, Ac10 Firmware 2025-07-07 7.5 High
Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacker to execute arbitrary code via the Virtual_Data_Check function in the bin/httpd component.
CVE-2024-0924 1 Tenda 2 Ac10u, Ac10u Firmware 2025-06-17 4.7 Medium
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-45779 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-13 9.8 Critical
Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.
CVE-2025-44175 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-13 5.4 Medium
Tenda AC10 v4 V16.03.10.13 is vulnerable to Buffer Overflow in the GetParentControlInfo function.
CVE-2025-5629 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-06 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2023-45481 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-05 9.8 Critical
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
CVE-2025-0528 1 Tenda 6 Ac10, Ac10 Firmware, Ac18 and 3 more 2025-05-28 7.2 High
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-4896 1 Tenda 2 Ac10, Ac10 Firmware 2025-05-27 8.8 High
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/UserCongratulationsExec. The manipulation of the argument getuid leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2022-42163 1 Tenda 2 Ac10, Ac10 Firmware 2025-05-15 9.8 Critical
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.
CVE-2022-42171 1 Tenda 2 Ac10, Ac10 Firmware 2025-05-15 9.8 Critical
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo.
CVE-2022-42170 1 Tenda 2 Ac10, Ac10 Firmware 2025-05-15 9.8 Critical
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
CVE-2022-42169 1 Tenda 2 Ac10, Ac10 Firmware 2025-05-15 9.8 Critical
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/addWifiMacFilter.