Filtered by vendor Tenda Subscriptions
Filtered by product Ac10u Subscriptions
Total 7 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-10280 1 Tenda 20 Ac10, Ac10 Firmware, Ac10u and 17 more 2024-11-01 6.5 Medium
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2023-44020 2 Tenda, Tendacn 3 Ac10u, Ac10u, Ac10u Firmware 2024-09-24 9.8 Critical
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
CVE-2023-44021 2 Tenda, Tendacn 3 Ac10u, Ac10u, Ac10u Firmware 2024-09-24 9.8 Critical
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function.
CVE-2023-44022 2 Tenda, Tendacn 3 Ac10u, Ac10u, Ac10u Firmware 2024-09-24 9.8 Critical
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-44023 2 Tenda, Tendacn 3 Ac10u, Ac10u, Ac10u Firmware 2024-09-24 9.8 Critical
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2024-2853 1 Tenda 2 Ac10u, Ac10u Firmware 2024-08-01 6.3 Medium
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0924 1 Tenda 2 Ac10u, Ac10u Firmware 2024-08-01 4.7 Medium
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.