| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security flaw has been discovered in Tenda AC8 16.03.50.11. This affects the function route_set_user_policy_rule of the file /cgi-bin/UploadCfg of the component Web Interface. The manipulation of the argument wans.policy.list1 results in os command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. |
| A weakness has been identified in Tenda AC8 up to 16.03.50.11. This vulnerability affects the function doSystemCmd of the file /goform/SysToolChangePwd of the component HTTP Endpoint. This manipulation of the argument local_2c causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. |
| A vulnerability was identified in Tenda AC8 16.03.50.11. Affected by this issue is the function check_is_ipv6 of the component IPv6 Handler. The manipulation leads to reliance on ip address for authentication. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. |
| A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
| A flaw has been found in Tenda AC8 16.03.33.05. Affected by this vulnerability is an unknown functionality of the file /goform/fast_setting_wifi_set of the component Embedded Httpd Service. This manipulation of the argument timeZone causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. |
| A vulnerability was detected in Tenda AC8 16.03.33.05. Affected is the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet of the component httpd. The manipulation of the argument shareSpeed results in buffer overflow. The attack may be launched remotely. The exploit is now public and may be used. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo. |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function. |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg. |
| Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg. |