CVE-2017-8837 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
Cleartext password storage exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The files in question are /etc/waipass and /etc/roapass. In case one of these devices is compromised, the attacker can gain access to passwords and abuse them to compromise further systems. | ||||
CVE-2017-8839 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
XSS via orig_url exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The affected script is guest/preview.cgi. | ||||
CVE-2017-8840 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
Debug information disclosure exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. A direct request to cgi-bin/HASync/hasync.cgi?debug=1 shows Master LAN Address, Serial Number, HA Group ID, Virtual IP, and Submitted syncid. | ||||
CVE-2017-8835 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
SQL injection exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. An attack vector is the bauth cookie to cgi-bin/MANGA/admin.cgi. One impact is enumeration of user accounts by observing whether a session ID can be retrieved from the sessions database. | ||||
CVE-2017-8841 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
Arbitrary file deletion exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The attack methodology is absolute path traversal in cgi-bin/MANGA/firmware_process.cgi via the upfile.path parameter. | ||||
CVE-2017-8838 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
XSS via syncid exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The affected script is cgi-bin/HASync/hasync.cgi. | ||||
CVE-2017-8836 | 1 Peplink | 12 1350hw2 Firmware, 2500 Firmware, 380hw6 Firmware and 9 more | 2024-08-05 | N/A |
CSRF exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The CGI scripts in the administrative interface are affected. This allows an attacker to execute commands, if a logged in user visits a malicious website. This can for example be used to change the credentials of the administrative webinterface. |