Search
Search Results (7 CVEs found)
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-43553 | 1 Ui | 2 Edgemax Edgerouter, Edgemax Edgerouter Firmware | 2025-04-24 | 8.8 High |
A remote code execution vulnerability in EdgeRouters (Version 2.0.9-hotfix.4 and earlier) allows a malicious actor with an operator account to run arbitrary administrator commands.This vulnerability is fixed in Version 2.0.9-hotfix.5 and later. | ||||
CVE-2023-2373 | 1 Ui | 3 Edgemax Edgerouter Firmware, Er-x, Er-x-sfp | 2025-01-30 | 6.3 Medium |
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability. | ||||
CVE-2023-31998 | 1 Ui | 4 Aircube, Aircube Firmware, Edgemax Edgerouter and 1 more | 2024-11-21 | 7.5 High |
A heap overflow vulnerability found in EdgeRouters and Aircubes allows a malicious actor to interrupt UPnP service to said devices. | ||||
CVE-2021-22909 | 1 Ui | 2 Edgemax Edgerouter, Edgemax Edgerouter Firmware | 2024-11-21 | 7.5 High |
A vulnerability found in EdgeMAX EdgeRouter V2.0.9 and earlier could allow a malicious actor to execute a man-in-the-middle (MitM) attack during a firmware update. This vulnerability is fixed in EdgeMAX EdgeRouter V2.0.9-hotfix.1 and later. | ||||
CVE-2020-8282 | 1 Ui | 4 Edgemax Edgepower 24v, Edgemax Edgepower 24v Firmware, Edgemax Edgepower 54v and 1 more | 2024-11-21 | 8.8 High |
A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution. | ||||
CVE-2020-8234 | 1 Ui | 12 Edgemax Firmware, Ep-s16, Es-12f and 9 more | 2024-11-21 | 9.8 Critical |
A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection. | ||||
CVE-2017-0938 | 1 Ui | 4 Airmax Ac, Airos, Edgemax and 1 more | 2024-11-21 | 7.5 High |
Denial of Service attack in airMAX < 8.3.2 , airMAX < 6.0.7 and EdgeMAX < 1.9.7 allow attackers to use the Discovery Protocol in amplification attacks. |
Page 1 of 1.